Meeting Banner
Abstract #1395

Arrhythmia Insensitive Rapid Cardiac T1 Mapping Pulse Sequence: In Vitro Study

Michelle Fitts1, 2, Elodie Breton3, Eugene G. Kholmovski2, 4, Derek J. Dosdall2, 5, Sathya Vijayakumar, 24, Kyung P. Hong1, 2, Ravi Ranjan2, 5, Nassir F. Marrouche2, 5, Leon Axel6, Daniel Kim2, 4

1Bioengineering, University of Utah, Salt Lake City, UT, United States; 2CARMA Center, University of Utah, Salt Lake City, UT, United States; 3ICube, Strasbourg University, Strasbourg, Alsace, France; 4UCAIR, Department of Radiology, University of Utah, Salt Lake City, UT, United States; 5Internal Medicine, University of Utah, Salt Lake City, UT, United States; 6Department of Radiology, New York University, New York, United States

We present a cardiac T1 mapping pulse sequence based on saturation recovery, which is arrhythmia-insensitive and rapid (AIR) for assessment of diffuse fibrosis. We compared its performance against the conventional cardiac T1 mapping inversion recovery based method, MOLLI, which is sensitive to heart rate and rhythm conditions, using an IR fast spin-echo sequence for reference. In vitro studies demonstrated that T1 measurements made by AIR were more precise and accurate than MOLLI at different heart rate and rhythm conditions. More work is needed to validate diagnostic accuracy and precision in patients with tachycardia and/or arrhythmias.

Keywords

accuracy accurate achieve acquisition acquisitions addition agent arrhythmia arrhythmias assess assessment background bandwidth beats bioengineering body breath calculation cancel cardiac charts chloride circulation city coefficient coll concentrations conditions constant constructed continuously correct customized delay density detect device diagnosis diagnostic differentiate diffuse duration edges effective elected enhancement equation error extracellular fast fibrosis field fitting focal free furthermore gadolinium generate gold healthy heart hold hong inherently insensitive internal inversion irregular lack lake late least linear long look magnetization manganese mapping maps matrix measured medicine minute modality modified monitoring myocardial myocardium needed nine noise normalized parallel patchy patient patients performance performances phantom phantoms pixel precession precision preparation prolonged proven pulse pulses quantification radiology ranging rapid readout recovery relevant repeatability repeated requires respectively rhythm rhythms root salt saturation scaling scanner sensitivity shot simulated simulator slice space specifically spin square steady tachycardia tissue trigger triggering uniformity unit unknown validate variation vials vitro washout whole widely yields