Clinical Application of 3D VIBE CAIPIRINHA-DIXON for Non-Enhanced Imaging of the Pancreas Compared to a Standard 2D Fat-Saturated FLASH

Stefan Haneder1, Katrin Koziel1, John N. Morelli2, Philipp Riffel1, Stefan O. Schoenberg1, Henrik J. Michaely1

1Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Mannheim, Baden-Wrttemberg, Germany; 2Scott and White Memorial Hospital and Clinic, Texas A&M University Health Sciences Center, Temple, TX, United States

The study compares a fast 3D VIBE sequence with Dixon fat saturation and CAIPIRINHA acceleration techniques (3D VIBECAIPI-DIXON) to a standard 2D FLASH sequence with spectral fat saturation and conventional GRAPPA acceleration technique (2D FlashGRAPPA-fs) for non-enhanced imaging of the pancreas in an intra-individual clinical setting. Qualitative assessments and semi-quantitative signal ratio measurements were performed. To complement this clinical data, we acquired quantitative phantom measurements to obtain objective signal-to-noise ratios. 3D VIBECAIPI-DIXON enables robust pancreatic imaging with an acquisition time of 12 seconds, providing homogenous fat suppression and a higher pancreas to fat signal ratio than conventional 2D FlashGRAPPA-fs.

Keywords

acceleration acquisition additional administration advanced agent agreement aliasing allows although analyzed application approved approximately artifacts audience axial baden better blurring body calculation channel characterization clinic clinical clinicians color combination comprised contrast controlled cylindrical delineated delineation diagnostic differ distribution enables encoded enhanced evaluated examined fast faster female flash head health hospital identified improved in vivo included independently indications individual institute inter intra intravenous john kappa leading lesion lesions liver male maps materials medical medicine memorial motion muscle noise nuclear organs overall pancreas pancreatic panel parallel part partial parts patient patients periods phantom preference preferred preserving prevent prior providing quality quantitative radiologists radiology random reader readers reasons reduced regard repeated resolution retrospective robust saturated saturation sciences sector semiquantitative setting significantly slice spatial specializing spectral spleen statistically subject suppression suspected system target temple treatment tumor univariate unweighted upper versus vibe views visceral visible volume white year years zoomed