Meeting Banner
Abstract #3990

Glycogen Chemical Exchange Effects in 1H-MRS and Glyco-CEST at 3T and 7T

Ronald Ouwerkerk1, Yee Kai Tee2, Craig K. Jones3, 4

1Biomedical and Metabolic Imaging Branch, NIH/NIDDK, Bethesda, MD, United States; 2Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford, United Kingdom; 3F.M. Kirby Research Center for Functional Brain Imaging , Kennedy Krieger Institute, Baltimore, MD, United States; 4Division of MR Research, The Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, United States

Glycogen can be measured in vivo with localized 1H-MRS or glycoCEST imaging. The chemical exchange between water and glycogen makes glycoCEST possible, but could lead to errors in water-suppressed 1H-MRS. We used glycoCEST and water-suppressed 1H-MRS on glycogen phantoms in physiological buffers to investigate this error source. The CEST effect was limited to the downfield H1 proton of glycogen. Varying water-suppression RF power level showed saturation transfer H1, but not on the upfield glycogen protons. The glycoCEST water reduction correlated with the concentrations estimated with 1H-MRS on the upfield peaks. Thus, both methods could be used to study glycogen metabolism.

Keywords

accurately affected appear around artifact artifacts asymmetry attenuations axial bath biomedical biopsy blue brain branch buffer buffers cause chemical chloride clear complement concentration concentrations constrained corrected correlated crucial dark decrease dependent deposits derived described dialyzed diminish dissolved division domain element engineering ethanol exact exchange exchanging fitted fraction function functional glucose glycogen good hardly hindered immersed in vivo increasing institute insulated invest investigated johns kept known light liter liver local materials measured medicine metabolic muscle natl nine obesity offset optimum option oxford peak peaks phantom phantoms physiological plastic plus power powers prepared press protons providing pulse pulses quantification quantified radiological radiology recorded reduce regulation remove residual rolling sample samples saturation scale scanner school science separate series settings seven sherry side sigma solution solutions spatial spectra spectroscopy spectrum spurious squares steps storage structure subtracting summed suppressed suppression taken train triangles tube tubes type uncovering understanding units unless unsaturated upfield variations varying vibration volume water whereas