Meeting Banner
Abstract #3905

MR Imaging of ex-vivo Mouse Joints on a Clinical 3T System with Diagnostic SPION Imaging Using DUTE in an Arthritis Model.

Lindsey Alexandra Crowe1, Frank Tobalem2, Marije Koenders3, Eline Vermeij3, Fons A. van de Loo3, Azza Gramoun1, Jatuporn Salaklang4, Anthony Redgem4, Alke Petri-Fink5, Heinrich Hofmann6, Wim van der Berg3, Jean-Paul Valle1

1Radiology / Faculty of Medicine, Geneva University Hospital, Geneva, Switzerland; 2Radiology, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland; 3Department of Rheumatology, Rheumatology Research and Advanced Therapeutics,, Radboud University Nijmegen Medical Centre, Nijmegen, Netherlands; 4Adolphe Merkle Institute, Universit de Fribourg, Fribourg, Switzerland; 5Adolphe Merkle Institute and Chemistry Departement, Universit de Fribourg, Fribourg, Switzerland; 6Institute of Materials, Powder Technology Laboratory, EPFL, Lausanne, Switzerland

Many pre-clinical studies are carried out on clinical MRI systems due to translational possibilities and availability of technology. For small sample sizes, an adapted coil to give high signal intensity is needed. Diagnostic potential of signal loss and positive contrast difference Ultrashort Echo (dUTE) sequences for iron oxide nanoparticle detection (amino-PVA-SPIONs) was compared in a mouse model of antigen induced arthritis. SPION administration routes and doses in arthritic and control knees are compared for synovial uptake with high sample throughput.

Keywords

ability able absence accumulate accumulation achieved addition amino amount anatomical applying around arranged arthritic arthritis articular artifacts avoided bone called carried chemistry clarity clinical coil colloid committee conformance consisted consistent contrast control days decrease decreased described detect detectable detection diagnostic dose drug easily efficient enough ethical evolution evolving explain faculty false fast field fink forward frank giving grade gradient graph hand hour identify illustrated in vivo induced injected injection institute institution intensity interface intra involving iron isotropic joints knee knees laboratory landmarks loss macrophages making mandatory marrow materials matrix medical medicine mice middle minutes model monitor mouse oxide paradoxical paramagnetic particles performance period petri positive positives potential presence previously projections protocol publications quantifiable quantification quantify radial radiology rapidly related resolution response robust route sacrificed samples saturation scanner scanning score scores scoring significance spatial specimen specimens statistically strong studies subtraction super system therapeutics throughout took treatment trio ultrashort uptake variation vascular vibe whereas whole