Time-Consistent Non-Rigid Motion Compensation for 3D DCE-MRI of the Entire Liver

Marijn van Stralen1, Hanke J. Schalkx2, Harrit W. Mulder1, Kenneth Coenegrachts3, Maarten S. van Leeuwen2, Wouter B. Veldhuis2, Josien P.W. Pluim1

1Image Sciences Institute, UMC Utrecht, Utrecht, Netherlands; 2Radiology, UMC Utrecht, Utrecht, Netherlands; 3Radiology, AZ St.‐Jan Brugge‐Oostende AV, Brugge, West-Vlaanderen, Belgium

Recent developments have enabled high-resolution dynamic contrast-enhanced MRI (DCE-MRI) of the entire liver. However, breathing and other organ motion hampers the current clinical use of DCE-MRI for perfusion analysis. Moreover, intensity change as a result of contrast perfusion challenges existing motion correction techniques. We propose a temporally consistent motion compensation method based on the integrated 3D + time alignment of the gradient magnitude of the image intensity. It is shown that time-consistent non-rigid registration outperforms temporal independent registration by measuring surface errors on manual liver segmentations. These results promise improved perfusion analysis (eg. pharmacokinetic modeling) of abdominal organs using DCE-MRI.

Keywords

affine alignment although anatomy applicability applicable arterial assume axis breath breathing caused characteristics chosen clinical compensate compensation computation consistence consistency consistent contour contours contrast control correlation counterpart cross decreased deformable deformation deformations delineation developments deviation diagnosis diffuse disease displayed distances dynamic enhanced entire evaluated evaluation evidence expressed extension field final five focal focuses frames free furthermore generated gradient green grid hampers holds horizontal illustrates improved independent independently influence injection integrated intensity kidney kidneys labeling length lesions liver magnitude manual manually mapping mass matrix measured measuring median metric minimization minutes model modeling moreover motion need novel ongoing organ organs orthogonal outer pancreas patient patients performance perfusion phys prostate qualitative radiology random recent registered registration registrations resolution rigid rigidly sampling scanned sciences secondly segmentation segmentations seven similarity since slice slices spin spleen spline strategy summarized superiority surface surrounding susceptibility table task temporal temporally thrive tool transformation transformed treatment unregistered validated validation variance visualization