Meeting Banner
Abstract #1836

Self-Resonant Swiss Roll Structures as Semi-Active Device Visualization Method for Interventional MRI

Mandy Kaiser1, Markus Detert2, Urte Kgebein1, Hans-Peter Schulze3, Bertram Schmidt2, Georg Rose1

1Department of Healthcare Telematics and Medical Engineering, Otto-von-Guericke University, Magdeburg, Sachsen-Anhalt, Germany; 2Department of Microsystems Technology, Otto-von-Guericke University, Magdeburg, Sachsen-Anhalt, Germany; 3Department of Theoretical Electrical Engineering, Otto-von-Guericke University, Magdeburg, Sachsen-Anhalt, Germany

During MR-guided minimal-invasive interventions the precise positioning of the instruments has a high impact on the treatment outcome. In order to get a visual verification of the instruments position, several highlighting methods such as resonant markers have been developed. This paper investigates the usability of self-resonant swiss roll structures as semi-active visualization method. Several resonant markers were fabricated and analyzed regarding electrical parameters and visibility within the MR image. The achieved quality factors range from 40 to 91. Severely high contrast-to-noise ratios were measured with all markers. Further investigations should concentrate on a miniaturization of the fabricated markers.

Keywords

achieved active adapt adjustable aluminum amplification applicability applications applying arbitrary around artifacts audience background besides biopsies biopsy bulky called capacitors catheters characterization clinical coils conductors contrast copper correction coupling deal decrease determined device dimensions directly discrete electrical enable engineering enhanced entire examined examines excited field foil foils frequencies frequency full furthermore generated geometrical guided guiding heat hence holden holders housed inductive inside instrument instruments interventions invasive kaiser laminated landmarks layer lead leads like magnetism majority manufactures marker markers matrix metallic minimal modality motion necessary needed needle needles network noise nonlinear ohmic opportunity orientated outside oxidation oxidized paper percutaneous perpendicular peter phantom phenomena physicians polymer positioning precise principle process proven publications realized relatively resonant roll rolls rose scanner scientists sections self semi shaped shrinking slice soft spins square strips structure structures suitable suited summarizes superior swiss target technology theoretical thinner tissue treatment tube tubes tuned vicinity visibility visualization visualizing water waterproofing wire