Meeting Banner
Abstract #1552

Simultaneous Measurement of GFR by DCE-MRI and FITC-Sinistrin Clearance in Rats at 3.0 T

Frank G. Zllner1, Daniel Schock-Kusch2, Sandra Bcker2, Sabine Neudecker2, Norbert Gretz2, Lothar R. Schad1

1Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Baden-Wrttemberg, Germany; 2Medical Research Center, Medical Faculty Mannheim, Heidelberg University, Mannheim, Baden-Wrttemberg, Germany

Recent clinical techniques for the estimation of GFR, such as clearance of inulin or sinistrin, scintigraphy with radio-labeled markers, and creatinine clearance are limited. Recent techniques to overcome some of the mentioned limitations are dynamic contrast enhanced magnet resonance imaging (DCE-MRI) or transcutaneous approaches based on fluorescent tracer molecules. The goal was to investigate if a simultaneous measurement was feasible and how MRI-GFR and optical-GFR correlate.Simultaneous measurement of the GFR by two non-invasive techniques namely, DCE-MRI and transcutaneous FITC-sinistrin clearance in rats is feasible. Furthermore, good agreement between the measured GFR values in healthy animals could be achieved.

Keywords

acquisition administered afterwards agent allow anesthetized angiography animal approaches array assisted back background baden better biomedical bolus bottom channel chemistry clearance clinical combination compartment computer consuming continuously contrast converted copper correlate cortex coverage days detected detection devices diagnose diagnostics dial dynamic eight electronics enhanced estimation exaltation example excretion faculty failure feasible femoral filtration fitting fixed flow fluorescent flush foil frank free goal half healthy hours immediately influence injected inside intervals intravenously invasive invest investigate investigative kidney kidneys labeled life limitations limited manually markers materials matrix measured medical medicine mentioned miniaturized minute minutes model molecules monitor morphological myers namely nominal optical original outcome overcome overlaid parametric powerful previously progression quantification radiation radio rapid rats receive recent reception recorded reduced removing renal resolution resolved respectively saline scanner segmented sensor shielded side simultaneous simultaneously skin slices solution song started stochastic table temporal thereafter tracer trajectories treatment tubular turbo twist upper vein volume volumes volumetric