Meeting Banner
Abstract #1339

Assessment of Energy Loss in Aortic Stenosis and Age-Matched Controls Using Bayesian Multipoint Phase-Contrast MRI

Christian Binter1, Robert Manka1, 2, Simon H. Suendermann3, Verena Knobloch1, Sebastian Kozerke1, 4

1Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland; 2Dept. of Cardiology, University Hospital Zurich, Zurich, Switzerland; 3Division of Cardiovascular Surgery, University Hospital Zurich, Zurich, Switzerland; 4Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom

Phase-contrast MRI offers the possibility to obtain both velocities and Turbulent Kinetic Energy, making it possible to quantify the energy loss due to aortic stenosis. In this work patients and age-matched controls are compared and test-retest variability is investigated. 4D flow measurements with multiple encoding velocities in the aortic arch of 3 patients and 18 healthy volunteers were performed. The results show that the physiological range of TKE in the ascending aorta shows only little variation with age and significant differences between patients and healthy controls were found.

Keywords

addition aging alone although anatomy aorta aortic application approval arch around ascending assessment best biomedical board cardiovascular caused channel clinical coil college combined comparability compensated conjunction contrast control controls correlation denotes density dependency dependent dept derived differs disease distribution division dynamic efficiency eighteen employing encoded encoding energy engineering ethics eventually exact facilitate flow fluid formation gold gradient gradients greatly healthy heart heat holds hospital indexes indicate indicated influence informed insensitivity investigated kinetic king larger leads little load local loss lost maps matched matrix measure measured minor modeled moderate moment navigator nominal noninvasive normalized offers ongoing overall patient patients patterns peak physiological population positioning possibility potential pronounced proportional providing quantitative ranging recirculation recruited reduction related repeatability replacement reproducibility resolution respectively retest scaling scheduled sciences severe severity slice slices spoiled stored straightforward stroke studies subject subjects suggest surgery systolic temporal told training turbulent twenty variance variation velocities velocity vessel visible volume volunteers years