Improved Fat Signal Suppression for Coronary MRA at 3T Using a Water-Selective Adiabatic T2-Prep Technique

Andrew J. Coristine1, 2, Ruud B. van Heeswijk, 23, Matthias Stuber, 23

1CIBM-CVMR, Centre Hospitalier Universitaire Vaudois , Lausanne, VD, Switzerland; 2FBM, Universit de Lausanne, Lausanne, VD, Switzerland; 3CIBM-CVMR, Centre Hospitalier Universitaire Vaudois, Lausanne, VD, Switzerland

At high field, B0 and B1 inhomogeneities may complicate fat saturation strategies, such as CHEmically Selective Saturation (CHESS) pulses, which are dependant on precise excitation angles and precessional frequencies. These fat saturation pulses, which are necessary for unambiguous visualization of cardiac anatomy, are often used in conjunction with magnetization preparation modules, such as T2 Preparation (or T2-Prep), to improve blood/myocardium contrast. By modifying an adiabatic T2-Prep to be water-selective, off-resonance frequencies can be suppressed - adding an intrinsic fat signal attenuation that is less sensitive to B0 and B1 inhomogeneities - while preserving the T2-Prep's added contrast. Numerical simulations, phantom validation, and initial in vivo results are presented.

Keywords

abdominal acquisition added adding addition additional adiabatic adults affected alone analyzed anatomy artery background bandwidth blood blue bottom bubble chess clinical color combination combined compartments complicate considered contrast coronary curve dashed degrees determined doped effective efficacy encompassing except excitation excite field final fraction frequencies frequency functions gated gradient healthy heartbeat homebuilt ideal immediately improve improved improving in vivo incorrect indicates inhomogeneities inhomogeneity initial intensity intrinsic inversion known longitudinal magenta magnetization matrix measured mimic modifying modules myocardium navigator necessary noise numerical often paired partitions phantom potential precise predict predictions prep preparation preserving prior profiles pulse pulses recovery reduce reduced reformatted regarded remains resonant robustness sample saturation scale scanned scanner sector segmented select selected selective sharp sharpness significance significantly simulated simulation simulations slice soap space spins spoiled statistical statistically strategies strategy student suppressed suppresses suppression table tailed targeted tipped tissue transverse triggered trio typical unambiguous validate validation variation varied various vessel volume volunteer water whereas