Quantitative Comparison of Morphometric Data from Multi-Echo MPRAGE with Variable Acceleration and Different Head Coils

Ross W. Mair1, 2, Martin Reuter2, 3, Andr J. W. van der Kouwe2, Bruce Fischl2, 4, Randy Buckner1, 2

1Center for Brain Science, Harvard University, Cambridge, MA, United States; 2Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, United States; 3Dept. of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, United States; 4Computer Science and Artificial Intelligence Laboratory, Massachusetts Institute of Technology, Cambridge, MA, United States

The multi-echo MPRAGE (MEMPRAGE) sequence was implemented to reduce signal distortion by acquiring at a higher bandwidth and averaging multiple echoes to recover SNR while providing additional T2* information that can enhance cortical segmentation. Here, we validate the morphometric results obtained from a rapid 2-minute MEMPRAGE scan with four-fold acceleration by comparison to those from a 6-minute, 1 mm isotropic, two-fold accelerated MEMPRAGE scan acquired in the same session. The results indicate that the rapid 2-minute MEMPRAGE protocol can be used in place of the longer, higher-resolution MEMPRAGE scan without degradation of the quantitative morphometric results obtained.

Keywords

abnormal accelerated acceleration according acquisition affected aligned although analyzed anatomical anterior approved artificial audience automated averaging bandwidth biomedical brain burden channel cliff coil coils commonly computer concerns conducting contrast correlation correlations cortex cortical days decays degradation dependent dept derived determinations determined distortion echoes efficiency either employing engineering enhance ensure example excluded extremely failures favor female fold gave general global grants hardware head hence hospital human implemented in vivo included indicate informed insights institute intelligence intra isotropic laboratory linear local longer made male martin maximal measures mechanical minimal minute neuroanatomy novel optimal parallel permission place plots posterior previously probed protocol protocols pulse quantitative quantitatively randy rapid recover reduce registration regression reliability repeat repeatability repeatable researcher resolution retest robust scanned scanner scanners science segmentation session slices smaller software structural structure structures studies subject subjects summarized surf surface system target technology tool toolkit trio unaccelerated uncertainty upgrade validate variable volume volumes volumetric white written years yields