Meeting Banner
Abstract #0067

4D UTE Flow: A Novel 4D Ultra-Short TE Phase-Contrast MRI Technique for Assessment of Flow and Hemodynamics

Mo Kadbi1, Melanie S. Traughber2, Peter Martin2, Amir A. Amini1

1Elect. and Comp. Eng., University of Louisville, Louisville, KY, United States; 2Philips healthcare, Highland Heights, OH, United States

4-D flow MRI has been recently investigated in several studies for quantitative flow assessment and visualization of complex flow pattern. Conventional 4-D PC MRI is not promising technique in the presence atherosclerotic disease and vascular stenosis due to intravoxel dephasing secondary to disturbed blood flow, and turbulence distal to narrowing often resulting in flow-related artifacts. Ultra-short TE (UTE) PC MRI revealed a shorter TE and improvement in flow quantification in disturbed and turbulent blood flow in through-plane direction . To take advantage of 4-D flow MRI as well as short TE, UTE technique was combined with 4D flow imaging and a 4-D UTE PC MRI technique was investigated. The fusibility of this technique for comprehensive flow assessment in healthy carotid artery compared to conventional 4-D PC MRI was studied.

Keywords

abnormalities accurate addition anatomical annual aorta applying artery artifacts assessment auto axial benefits bifurcation bipolar bland blood cardiac carotid challenged characterization cine coil combined combines comp compensated complex comprehensive confidence contrast corrected correction correlation correspondence cycle delays demonstrating density disease distal disturbed eddy elect element encoded encoding error errors estimation expected fashion feasibility feasible field five flow flows frames future gradient gradients healthy heart heights identical illustrates imperfection improvement improves in vivo interleaved invasive investigated lobe located loss martin need note novel patterns peak peter phantom plot potential presence previous previously prior proposed proximal quantification quantitative radial read readout reasonable reduced reduces refocusing related reported representing requires resolution reveal revealed sampling scanner scanning secondary select selection sense sensitive separate several short shortened shortening shorter significantly simplicity slice slices slight software space spatial static strength studied studies subtracting suffer suffering system systolic take trajectory turbulence turbulent ultra valvular vascular velocity visualization volume volumes volunteers