Meeting Banner
Abstract #4213

MR-Microimaging on a 7T Whole-Body Scanner Featuring Ultrashort Detection Times and Magnetization Transfer Contrast

Christian Horn1, 2, Vladimir Juras1, 3, Stefan Ropele4, Andreas Berg1, 2

1MR-Center of Excellence,, Medical University of Vienna, Vienna, Austria; 2Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria; 3Department of Radiology, Vienna General Hospital, Medical University of Vienna, Vienna, Austria; 4Department of Neurology, Medical University of Graz, Graz, Steiermark, Austria

The combination of special, radial pulse sequences designed for the detection of ultra-short echo times (UTE, TEmin = 0.07 ms) with the clinically more established technique of magnetization transfer contrast promises a new image contrast in semi-solid tissue components or implants with very short T2 times (< 1 ms). A corresponding pulse sequence was evaluated on a custom designed MR microscopy gradient insert on a 7T human scanner. BSA phantoms, with different BSA to water concentrations, and biological samples were used to demonstrate the practical applicability of the sequence ex vivo.

Keywords

achieved achieving additionally adjustable albumin allow amplitude applicability application approx around artifacts available backbone berg best better biological biomedical biomedicine body bovine calcified cartilage caused chemical clinical clinically coils combination components composition contrast coordinate correlated corresponds coupling cross currently custom decay dependent designed detection detector encoded engineering excellence exchange excitation exhibits features featuring frequency function general gradient gradients graham highly horn human immediately imperfect impossible in vivo induced insert integrated intensity investigate invisible lateral liability limited linked magnetization manner materials medical meeting micro microns microscopy minimized mobility model motional nearly neurology novel occurs offset offsets patient performance performances phantom phantoms physics placed plastics polarization practical precedes profiles protons providing pulse radiology rapid readily reconstructed reduced reduction regarding remaining resolution resolutions resonant restriction samples saturation scanner scanners semi serum short since slice solid space spatial special spectral spiral strength strong structure substance system systems timing tissue tissues transfer ultrashort varied vertebral water weighing whole