Quantitation of Renal Perfusion in an Animal Model at 3T: A Comparison Between ASL and DCE-MRI

Fabian Zimmer1, Frank G. Zoellner1, Simone Hoeger2, Sarah Klotz2, Charalambos Tsagogiorgas3, Lothar R. Schad1

1Computer Assisted Clinical Medicine, Heidelberg University, Mannheim, Germany; 2Department of Medicine V, University Medical Centre Mannheim, Heidelberg University, Mannheim, Germany; 3Clinic for Anaesthesiology and Intensive Care, Heidelberg University, Mannheim, Germany

The assessment of kidney function by measuring renal microvascular perfusion is crucial to diagnose and treat renal diseases at an early stage of progression. MRI provides two techniques to assess renal perfusion: Dynamic contrast-enhanced (DCE)-MRI and arterial spin labelling (ASL). In this study, ASL has been established to quantitatively measure renal cortical perfusion in rats with unilateral ischaemic acute renal failure. The ASL estimates were compared against those obtained by DCE-MRI. Both methods are in good agreement and show no statistical differences. Furthermore, both methods depict significant blood flow differences between healthy and diseased kidneys.

Keywords

abdomen abdominal absolute acceleration acute agent agents aggravating agreement animal animals array arterial assess assessed assessment averaging axial basis biomedical blood calculating capable care cause challenges clinical close coefficient committee completely concentration congruency contrast cortical covered deconvolution depicting detection determined diagnose directly diseased diseases drawing dynamic endogenous ensure establish examined except excluded experiment express failure fair feasibility field flow flush frank function furthermore gadolinium global healthy house important included inhomogeneities injection input institutional intensive inter invasive inversion issues kidney kidneys leaving lewis magnetically manner manually maps matrix measure measured measuring medicine might minutes nominal normalized open overall partition perfusion phantom phys pixel placing post preparation procedures progression pronounced pulsed quality quantification rabbits rats receive recorded reduced regarding related relationship renal reported representative respectively respiratory risk scanner script selective significantly slab slice slices song spin stage statistical studies subtracting suppression table temporal transitions treat triggering trio true twist vein volume whereas whole