Meeting Banner
Abstract #3931

In Vivo Four-Dimensional Flow Analysis of Mechanically Assisted Ischemic Cardiomyopathy

MAGNA25Jeremy R. McGarvey1, 2, Walter R.T. Witschey, 23, Kevin J. Koomalsingh2, Norihiro Kondo2, Manabu Takebe2, Gerald A. Zsido2, Melissa M. Levack2, Christen M. Di

1Department of Surgery, University of Pennsylvania Health System, Philadelphia, PA, United States; 2Gorman Cardiovascular Research Lab, Harrison Department of Surgical Research, Glenolden, PA, United States; 3Department of Radiology, University of Pennsylvania Health System, Philadelphia, PA, United States; 4Department of Radiology, University Medical Center Freiburg, Freiburg, Germany; 5Department of Radiology, Northwestern University School of Medicine, Chicago, IL, United States

Development of ischemic cardiomyopathy is complex pathophysiologic process that is both challenging to describe and treat. Ischemic insult results in an increase in the zero-pressure volume (Vo) and residual volume, as defined by pressure-volume relationships and flow-sensitive 4D MRI respectively. A directed therapy that restores the V0 of the infarcted area has yet to be introduced or evaluated. We describe the flow changes associated with a novel epicardial active assist device. Using 4D flow-sensitive MRI, we have found that both systolic and diastolic flow is increased in the area adjacent to the infarct while being assisted, when compared to baseline.

Keywords

ability abnormal active allow alter altered amount animal apex applied arrow artery assist assistance assisted augment augments away blood card cardiovascular changing christen chronic circulation compatible conductance contractile contraction contrast creates cycle dead denoted described design designed device diastole diastolic dimensional directed dram dynamics early efficiency eliminating employ encoded encoding established evidence fail failing failure field finding flow fluid force functional gate gated geometry glen gradient health heart helium hereby improve improved in vivo included increasing infarct infarction inflating inflation local many mapping mechanical medical medicine minimal model moved multitude myocardial myocardium near negative neoprene novel outside patterns physiologic porcine positioned post pressure processing profile pulsation pulse quantify radiology rapid rapidly redistribute remodels remote removal residual resolution safely school sensitive software space spatial stark studies suction surface system systole systolic temporal therapies thresholding throughout towards transducer treatment trio turn twelve unassisted underwent velocity ventricle ventricular verse volume weighing wine zero