Meeting Banner
Abstract #3891

Feasibility of Detecting Myocardial Ischemia Using First-Pass Contrast MRI and Regadenoson

Pamela K. Woodard1, Matthew R. Lyons2, Cylen Javidan-Nejad1, Ibrahim M. Saeed3, Donna Lesniak4, Gary McNeal5, Agus Priatna5, Sven Zuehlsdorff6, Robert J. Gropler1

1Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, United States; 2Cardiology, Case Western School of Medicine, Cleveland, OH, United States; 3Cardiology, Saint Lukes Hospital, Kansas City, MO, United States; 4Mallinckrodt Institute of Radiology, Washington University School of Medicine, St., Louis, MO, United States; 5Siemens Medical Systems, Malvern, PA, United States; 6Siemens Medical Systems, Erlangen, Germany

Cardiac stress MR perfusion imaging requires an MRI compatible infusion pump for the administration of adenosine or a non-MRI compatible pump housed in the control room or beyond the 10-Gauss line. This later method requires high-pressure extension tubing running for some distance across the control room and/or scan room floor. This has the potential to compromise both the quality of the examination and patient safety. Regadenoson is a recently FDA-approved A2A receptor agonist which can be given intravenously in a single 400 microgram bolus. We hypothesize that a single injection of regadenoson could be used instead of an adenosine infusion to produce coronary vasodilatation and demonstrate myocardial ischemia during first-pass perfusion cardiac MRI. Forty-four patient were imaged. All but one patient tolerated the regadenoson cardiac MR perfusion examination. Regadenoson can be used safely in cardiac MR perfusion imaging to demonstrate ischemia.

Keywords

additional administered administration advance agent approved array artifact attenuation axis background beings beyond blood body bolus cardiac cardiology chest cine circulation city clinical clinically coil committee compatible compromise computed consisted contrast control coronary correction council days defect defects delayed detecting determine diagnostic distance distribution element emission enhanced evaluation exam examination examinations exams feasibility findings five floor flow flows flush fold free gauss heart hospital hotel human humans included infarct infusion injection instead institute international intravenously invasive least limiting long mace matched matrix medical medicine mering minutes motion myocardial nine nomenclature nonrigid noted objective overall pain pass patient patients perfusion photon potential power precession prepared pressure produce professionals pump quality radiology received recently receptor regarding registration requires resolution reversible room running safely safety saint school segment selective setting short shortly slice spine standardized statement steady stress subjects subsequently suggesting symptoms systems title tolerated tomographic tomography trial tubing underwent vascular velocity versus western