Abstract #3291

Novel FSE Method to Improve T2map Accuracy by Calculating B1map Simultaneously

Yoshihiro Tomoda1, Hitoshi Ikeda1

1MR Engineering, GE Healthcare Japan, Hino, Tokyo, Japan

Novel FSE method is proposed to improve the T2map accuracy by calculating B1map simultaneously without scan time elongation. Compared with the legacy CPMG method, T2 estimation error is low enough in a wider range of T2 and refocus FA. In addition, lower refocus FA is applicable to the proposed method, which would decrease SAR and increase the number of max slices per acquisition.

Keywords

account accuracy acquisition actual added addition additional align almost analytically angel applicable application applied around beyond calculating cartilage causes changing clinical curve decay decrease decreases degree degrees depends deteriorates deviation diagnosis difficult echoes elongation engineering enough equation equilibrium error especially estimation everywhere example excitation exponential extract fast fields fitting improve induces inhomogeneity japan larger legacy ligament longer magnetization magnitude measured merits mild minimized modified noise novel numerical observe offset optimized osteoarthritis perpendicular pixel proposed pulse pulses reduce reduced refocus residual robust separated severe short simulated simulation simultaneously slices soft spin stimulated sufficiently taken tendon theory tissues transmission unexpectedly usage useful versus white wider