Meeting Banner
Abstract #2438

A 3D Parametric Model for Imaging Normalization

Tiejun Zhao1, Kwan-Jin Jung2

1Siemens Healthcare USA; Siemens Medical Solutions USA, Inc., Pittsburgh, PA, United States; 2Psychology, Carnegie-Mellon University, Pittsburgh, PA, United States

Multi-channel receiving (Rx) coils have become a standard asset of routine MR imaging due to its improved signal-to-noise ratio and the parallel imaging capabilities. However, the image intensity variations from the receiving profile could be problematic for tissue segmentations and various quantification analyses. While the pre-scan normalization that acquires additional data using body coil provided a popular approach for removing this imaging shading artifact, a retrospective normalization can still be invaluable especially when the extra data is not available due to various reasons (e.g., the original protocol did not include a pre-scan for normalization or a uniform body coil is not available for some head only scanners or current most 7T scanners.) In this abstract, we proposed and demonstrated a simple 3D parametric model for modeling and removing the smooth image intensity variations presented in images acquired with multi-channel Rx coil.

Keywords

able abstract adequately advantage alleviated allow among analyses another anterior arrays artifact artifacts asset assumed available become better body brain brighter capabilities carried channel clear coil coils constant constants contrary control controls correction creating darker decreased define defines dell depend described determined determines dotted dual ensure error especially evident except excitation exhibited expansions extra feet final fitting fittings fixed flatter guess hand head illustrate improvement improvements include initial intensity invaluable journal linear linearly location manuscript march mask matrix medical middle might mild milder minimal model modeling much need noise nonlinear normalization normalized optimization parallel parametric pattern peripheral popular position posterior potentially problem problematic procedure process profile profiles proposed protocol psychology quantification radius reasons receiving reduce reduced remove removing residual retrospective routine scanners seemed segmentations selected sets shading slice slices slight slightly smooth square starting steepness steps still subsequent taking third tissue took toward transactions transition transmit unaltered uniform unknowns variations various