Meeting Banner
Abstract #2215

PTx Pulse Design with Explicit Hard Constraints on Local and Global SAR and Maximum and Average Forward Power

Bastien Guerin1, Matthias Gebhardt2, Elfar Adalsteinsson3, 4, Lawrence L. Wald1, 4

1Martinos Center for Biomedical Imaging, Dept. of Radiology, Massachusetts General Hospital, Charlestown, MA, United States; 2Siemens Healthcare, Erlangen, Germany; 3Dept of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, United States; 4Harvard-MIT Division of Health Sciences Technology, Cambridge, MA, United States

Electromagnetic simulations have shown that pTx pulse design with average forward power regularization does not constrain local SAR. We propose two pulse design interior point algorithms that explicitly constrain spatial fidelity, local and global SAR, average and maximum forward power. The first (second) minimizes excitation error (local SAR) while constraining local SAR (excitation error), global SAR and maximum/average power. We show the equivalence of these two approaches and their capability in handling large numbers of constraints without the need of defining a tradeoff parameter, giving more flexibility to the operator to explore the pulse design parameter space in real time.

Keywords

approaches arbitrary array attempted aver biomedical blue body capability chain circles comp complementary complex components compress compressing computation computer confirms conjunction constrain constrained constraints continuously control controlled convex correspondence cost coupling creating crosses curves decreasing depend dept design designed determined directly division duke electrical electromagnetic enforces engineering equivalent error evaluate evaluated excitation explicit explicitly explore family fidelity flexibility forward foundation free full functions general giving global gradient hard hardware health hospital improve incorporate incorporation institute interior jointly limited limits local making marginally matrices matrix metrics model modeled moreover must need noting observation operator optimization overestimation peak penalize phys power press problem profile propose protecting prove pulse pulses quadratic quantifying quickly radiology real realistic reduce regularization regularizing resolution scanner science sciences secs shimming simulations slice smaller solve solving space spatial spoke spokes strategy target technology term tissue transmit transverse trivial types uniform useful user usually varying versus virtual voltage ways yield yielding