A New Reference Agent Model for DCE-MRI That Exploits Selective Detection of Two 19F MRI Contrast Agents

Julio Crdenas-Rodrguez1, Christy M. Howison2, Terry O. Matsunaga3, Mark D. Pagel4

1Chemistry and Biochemistry, TheUniversity of Arizona Cancer Center, University of Arizona, Tucson, AZ - Arizona, United States; 2Arizona Research Labs, University of Arizona, Tucson, AZ, United States; 3Radiology, University of Arizona, Tucson, AZ, United States; 4Departments of Biomedical Engineering, Chemistry and Biochemistry , The University of Arizona Cancer, University of Arizona, Tucson, AZ, United States

The Reference Region Model has been proposed as an alternative method for evaluating DCE-MRI results without requiring an AIF, yet this method cannot account for changes in blood flow and hematocrit that affect the evaluation of vascular permeability. Instead of comparing DCE of a single contrast agent in two tissues, we propose a new model that compares two contrast agents in a single tissue, termed the Reference Agent Model. This report describes the selective detection of two 19F contrast agents in vivo under dynamic and multislice conditions, and opens the possibility of estimating the relative permeability of two CA because this new model is independent of blood flow and hematocrit.

Keywords

account accuracy accurately acquisition active activity affect agent agents allowed anatomical arterial atoms best biochemistry biomedical blood breast cancer catheter cells characteristics chemistry comparing composition computer conditions constants contrast control crown curves defined density derived describing detect detected detection determined determines developed differential difficult dynamic emulsion emulsions engineering enhancement equation equations equivalent estimating ether evaluating evaluation even excitation exploits extruded female filter fitted five flank flow fluorinated frequencies function generated geometry greatly identical identifying implement in vivo independent initiating injected input instead internal interpretation knowledge known labs light limitations liquids manually mark matrix mice minutes model mouse must next noise opens operation optimized permeabilities permeability placed possibility precision prepared process propose proposed pulse radiology regarding report rescaled resolution sampling scattering selection selective selectively series serve sets simulations simultaneous simultaneously singlet slice slices solid spin statistical studies subcutaneously tail temporal termed terry tissue tissues triplet tumor tumors uncertainty vary vascular vein vials volume yielded