Meeting Banner
Abstract #0711

1H MRS in the Human Spinal Cord at 7T Using a Combined RF Shimming & Travelling Wave Transmit Approach

Anke Henning1, 2, Wouter Koning2, Alexander Fuchs1, Alexander Raaijmakers2, Johanna J. Bluemink2, Erin L. MacMillan1, 3, Cornelius A.T. van den Berg2, Peter Luijten2, Peter Boesiger1, Dennis W.J. Klomp2

1Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland; 2University Medical Center Utrecht, Utrecht, Netherlands; 3Department for Clinical Research, University of Bern, Bern, Switzerland

Due to its non-invasive nature 1H MRS is of specific benefit to study alterations of biochemical processes in human spinal cord (SC) pathologies where performing biopsies is perilous. However, the finite size and deep location of the human SC limit the obtainable SNR at field strengths < 3T. Hence 1H MRS of the human SC at 7T is introduced to tackle the intrinsic SNR and spectral resolution problems and increase the number of quantifiable metabolites. A dual-channel RF shimming and travelling wave transmit approach is combined with adiabatic inner -volume saturated localization and a 30-channel receive array to obtain optimal SNR.

Keywords

accurate achieved acquisition adiabatic allowed antennas applicability array artifact attached attainable automatic bands basis berg biochemical biomedical biopsies broadband built central cervical channel chemical choline clinical close coil combined compensation comprises consent containing contamination cord corrected custom cycled deep described determination developments diameter dielectric differential displacement displaying distortions eddy element environment excellent exploit exploits exponential field finite flow fluctuations fluid forms free frequency gamma gave ghosting glutamate healthy henning homogeneous human impaired improved inner inside introduced invasive laser limit lipid local localization manual materials metabolites motion nature neck nervous numerically optimized pathologies patient performance peter pillow positioning press prior problem processes protocol pulse quality quantifiable quantification radiative receive receivers reception reduction regard regulations relatively respiratory sample saturated saturation schematic semi sensitivity separation setup shimming shot simulated spatial spectra spectral spectroscopy spin spinal strength strengths strong suppressed suppression susceptibility system third tool transmit valuable vapor volume volunteers water wave waveguide whole width