Meeting Banner
Abstract #4569

Arrhythmia Insensitive Rapid Cardiac T1 Mapping Pulse Sequence: in vivo Study

Michelle Fitts1, 2, Elodie Breton3, Eugene G. Kholmovski, 24, Derek J. Dosdall2, 5, Sathya Vijayakumar, 24, Kyung P. Hong1, 2, Ravi Ranjan2, 5, Nassir F. Marrouche2, 5, Leon Axel6, Daniel Kim2, 4

1Bioengineering, University of Utah, Salt Lake City, UT, United States; 2CARMA Center, University of Utah, Salt Lake City, UT, United States; 3ICube, Strasbourg University, Strasbourg, Alsance, France; 4UCAIR, Department of Radiology, University of Utah, Salt Lake City, UT, United States; 5Internal Medicine, University of Utah, Salt Lake City, UT, United States; 6Department of Radiology, New York University, New York, United States

We propose an arrhythmia-insensitive, rapid (AIR) cardiac T1 mapping pulse sequence based on saturation recovery, which is insensitive to heart rate and rhythm conditions, for quantification of diffuse fibrosis. We compared its performance against the conventional cardiac T1 mapping inversion recovery based method, MOLLI, which is sensitive to heart rate and rhythm conditions and requires a long breath-hold duration. In vivo studies demonstrated that T1 measurements made by MOLLI and AIR were strongly correlated, but in poor agreement. Our AIR pulse sequence may be clinically useful for assessment of diffuse myocardial fibrosis in patients.

Keywords

achieve acquisition acquisitions administration agent agreements analyses animals arrhythmia assess assessment averaging background bandwidth beats bias bioengineering bland blood blurring body breath calculation cancel cardiac centric circulation city clinically coefficient coil coll compensate consistently contrast correct correlation customized delay density developed difficulty diffuse distinguish dividing dogs dose duration elected equation excised experiment fibrosis field focal free gadolinium goats gold governing heart hold hong human humans ideal in vivo infarction inhomogeneity insensitive inter internal inversion irregular lake late limits long look magnetization male manually mapping maps matrix measured medicine minimize minute minutes modality myocardial myocardium noise parallel particularly patchy patients performance performances pixel pool poor post precession proposed proven pulse quantification radiology randomized rapid readout receiver recovery relevant repeatability repeatable requires resolution respectively respiration rhythm salt saturation scanners segment sensitivity shot sinus slightly software solving space spatial specified steady strongly subjects suspending temporal tissue unfortunately unknown upper useful ventricular view volunteer whole year yielded