Meeting Banner
Abstract #4460

Dynamic and Static MR Angiography of the Supraaortic Vessels at 3.0 T: Intraindividual Comparison of Gd-Based Contrast Agents at Single Dose

Harald Kramer1, Elisabeth Arnoldi1, Christopher J. Francois2, Andrew L. Wentland3, Konstantin Nikolaou1, Bernd J. Wintersperger4, Maximilian F. Reiser1, Thomas M. Grist2

1Institute for Clinical Radiology, Ludwig-Maximilians-University Munich, Munich, Bavaria, Germany; 2Department of Radiology, University of Wisconsin-Madison, Madison, WI, United States; 3Department of Radiology, University of Wisconsin - Madison, Madison, WI, United States; 4Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada

Several different contrast agents exist for MRI and Despite the fact these are all Gadolinium (Gd) based, they feature different characteristics. We performed static and dynamic MRA of the Carotid arteries with 3 different agents at single dose at 3.0T. Qualitative image quality as well as SNR, CNR and vessel sharpness was assessed. At equimolar doses 1.0 molar Gadobutrol demonstrates superior SNR / CNR to Gadobenate dimeglumine and Gadoterate meglumine with subjectively higher image quality in static and dynamic Carotid MRA. The decreased injected volume with Gadobutrol does not result in significantly different edge blurring of vessels.

Keywords

accuracy acquisition agent agents aiming albumin angiography appears applications approved arteries assessment audience automated axial bandwidth beneficial binding blinded blood blurring bolus carotid characteristics circulatory clinical components concentration confirm contrast decrease dedicated defined delay despite developed diagnostic directly done dose doses dynamic edge enhanced equal evaluated exam example exams excellent exclude exemplary exist experience extended extremities fact fashion favorable feature features field finding findings gadolinium good graph grist healthy house human indicates inferior initial injected injection institute interaction invest kappa least limited make matrix maximal media medical might minutes mixed models molar molecules morphologic optimize pairwise parallel pool prior profile protein protocols qualitative qualitatively quality quantitative radiologists radiology randomized rank rankings reached readers recorded reflect regard repetition representing resolution respectively scientists semi separately several sharpness shortened significantly since slice solutions spatial split standardized static statistical strengths subjectively superior system table target temp temporary tool underwent vascular vessel vessels volume volunteers weak