Meeting Banner
Abstract #4029

Quantification of Phosphoenolpyruvate in the Human Liver and Its Application in a Meal Study Employing 31P MRS

Alessandra Laufs1, Roshan Livingstone2, Maria Fritsch3, Julia Szendroedi4, Juergen Bunke5, Michael Roden1, 6, Jong-Hee Hwang1

1Institute for Clinical Diabetology, German Diabetes Center, Dsseldorf, Germany; 2Department of Radiology, Christian Medical College, Vellore, India; 3Medical University of Vienna, Vienna, Austria; 4Institute for Energy Metabolism, German Diabetes Center, Dsseldorf, Germany; 5Philips Healthcare, Hamburg, Germany; 6Department of Metabolic Deseases, University Clinics Dsseldorf, Dsseldorf, Germany

Changes in phosphoenolpyruvate (PEP) concentrations of the liver were quantified before and after a high-carbohydrate meal using 31P MRS in six healthy subjects at 3T. Quantification of PEP was performed using matching phantoms and an external reference in order to correct for excitation pulse profile, coil loading, B1 field inhomogeneity, T1 relaxation time (T1 = 0.82 0.16 s, separately assessed, N = 5)and the amount of liver fat. The concentration of PEP 140 min after the meal was significantly decreased from 1.14 0.22 mmol/l to 0.86 0.22 mmol/l (N = 6, p = 0.01, paired t-test).

Keywords

absolute acid acquisition adiabatic administrations alanine amount application approved assess assessed bell best biomedicine board body built capital carbohydrates channel circular clinical clinics coil college compounds concentration concentrations conditions consented considered containing content coronal correct decoupling decreased delay diabetes dietary employed employing energy excitation external extracts fall field future glucose goal hamburg healthy hepatic human humans importance important in vivo index ingestion inhomogeneity institute interface intermediate inversion investigate kcal knowledge least little liver loading local localize locally maria markedly mass matching material meal measured medical metabolic metabolism might mixed mobility molar needed networks noise note overlaps paired partly peak phantoms phosphate plot possibly potassium previous previously priori processing profile properly protein protocol proton publication pulse quantification quantify radiology receive receiver recovery recruited reflecting report reported resolution response revealed review role scanner sense separate series severe software spectrum standardized statistically statistics steam studied studies subjects transmitter transverse underwent uniform user volunteers whether whisker years