Meeting Banner
Abstract #3983

Quantification and Reproducibility of L-COSY in Human Brain at 7T

Gaurav Verma1, Hari Hariharan2, Rajakumar Nagarajan3, Manoj K. Sarma3, Ravi Prakash Reddy Nanga2, Edward James Delikatny2, M. Albert Thomas3, Harish Poptani1

1Department of Radiology and Radiation Oncology, University of Pennsylvania, Philadelphia, PA, United States; 2Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States; 3Department of Radiological Sciences, University of California Los Angeles, Los Angeles, CA, United States

Localized correlated spectroscopy (L-COSY) was developed for use in 7T whole-body scanners. L-COSY was tested for reproducibility in the occipital lobe of six healthy volunteers, and tested for versatility by scanning differing anatomy including basal ganglia, frontal lobe, dorso-lateral prefrontal cortex and parieto-occipital region in two volunteers. 2D spectra showed distinct resonances of gamma-aminobutyric acid, glutathione, lysine, isoleucine, choline group and other metabolites with voxels as small as 15.6ml. After quantification with prior-knowledge based peak fitting, coefficients of variation of metabolite ratios were found comparable to existing L-COSY studies at lower field strengths.

Keywords

ability able acceptable acid acquiring acquisition additionally ages aggressive analogous anatomical anatomy applied assessing basal body brain channel chemical choline coefficient coil column concentrations conditions containing correlated cortex coupled coupling cross custom detects diagonal dimensions dispersion even evolution except extracted field fields filters fitting free frontal ganglia glutamate head healthy human identifying implemented in vivo incorporating increments indicated indicating indirectly integrals intensity interactions knowledge lead lobe lobes localized locations lysine male materials measured metabolic metabolite metabolites middle minutes model monitoring much occipital oncology optimize overlap padding parietal pathological peak peaks phantom physiological post press prior processed profile profit program pulse quantification quantified radiation radiological radiology receive reliability reliably reproducibility resolve resolved respect respectively routines scanner sciences sensitivity several shimming simple smaller specificity spectra spectral spectroscopy spectrum strengths studies subjects successfully suppression systems table taken terms timing took transmit typical typically uniquely vapor variation various versatility viability visible volume volunteer volunteers water white whole