Abstract #3545

Rapid Isotropic Resolution Imaging of the Articular Cartilage of the Knee Joint at 3.0T Using VIPR-IDEAL

Larry Hernandez1, Leah C. Henze Bancroft2, Walter F. Block3, 4, Richard Kijowski5

1Medical Physics, University of Wisconsin - Madison, Madison, WI, United States; 2Biomedical Engineering, University of Wisconsin - Madison, Madison, WI, United States; 3Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, United States; 4Medical Physics, University of Wisconsin, Madison, WI, United States; 5Radiology, University of Wisconsin, Madison, WI, United States

VIPR-IDEAL can produce fat-suppressed, high isotropic resolution images of the knee joint in 5 minutes at 3.0T. VIPR-IDEAL, VIPR-ATR, FSE-Cube, IDEAL-GRASS, and IDEAL-SPGR sequences were performed on both knees of four volunteers and SNR/CNR was measured using a double acquisition addition/subtraction method. VIPR-IDEAL had similar cartilage and fluid SNR as VIPR-ATR and significantly higher (p<0.01) cartilage and fluid SNR than FSE-Cube, IDEAL-GRASS, and IDEAL-SPGR. VIPR-IDEAL had significantly greater (p<0.01) suppression of bone marrow fat signal than VIPR-ATR. Our study shows that VIPR-IDEAL has the same high SNR efficiency for evaluating articular cartilage as VIPR-ATR but provides superior fat suppression.

Keywords

accurate achievable acknowledgments addition adequate adjacent advantage allows alternating appearance array arrows articular assessment avoid away bandwidth better biomedical block bone bright cartilage channel clearer clinical close coil collection consisted contrast create cube decomposition described detection determine discovery double edema efficiency efficient engineering especially evaluate evaluating examination examinations extremity field fluid frequency grass greater hardware highly ideal improved in vivo interface interfaces isotropic iterative joint keeping knee knees least lesion lesions ligaments maintain maintaining major manipulating marrow matrix maximal measures medical menisci metallic minute minutes mixed must needed noise note nulls optimized organ orientation orthopedic osteoarthritis pain parallel partial pass patients peaks performance physics placed post practice previously produce produces projection quality quantitative radial radiology rapid reconstruction reeder reformat removing resolution robust scanner separate short significantly sources spatial spectrum squares strengths strong structures studies subtraction suited superior support suppression surface tears tissue trajectory twice utilizes vastly view visualized volume volunteer volunteers water whether