Meeting Banner
Abstract #3062

Variability of CBF Calibration Using Venous Output Function in DSC-MRI of Rat Brains

I Chi Liu1, 2, Tsong-Hai Lee3, Ching-Chung Liang4, Ho-Ling Liu1, 5

1Department of Medical Imaging and Radiological Sciences, Chang Gung University, Taoyuan, Taiwan; 2Department of Medical Physics, Koo Foundation Sun Yat-Sen Cancer Center, Taipei City, Taiwan; 3Department of Neurology and Stroke Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan; 4Department of Obstetrics and Gynecology, Chang Gung Memorial Hospital, and Chang Gung University College of Medicine, Taoyuan, Taiwan; 5Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Taoyuan, Taiwan

Accurate estimation of arterial input function (AIF) is crucial for the CBF quantification using DSC-MRI. In small animals, AIF is difficult to identify due to the inevitable partial-volume effects. This study aimed to investigate the feasibility of using a venous output function (VOF) for calibrating the AIF in rats, and evaluate the deviation caused by the selection of VOF within sagittal sinus. The results showed that using the ratio of areas under the curve from VOF versus AIF after a gamma-variate fitting yielded the most stable CBF calibration. The uncertainties of resulted CBF values were in the range of 8-28%.

Keywords

absolute accurate adjacent affected aimed among amount another appear array arterial artery assessment averaging biomedical blood brain brains brief calibrate calibrated calibrating calibration cancer caused cerebral city coefficient coil college concentration consistent consuming contrast correct corrected correspondingly covered curve curves decomposition deconvolution decreasing delta dementia desirable determined determining deviation diagnoses diseased dynamic exhibited experiment feasibility feasible female femoral fixed flow foundation function general gradient gynecology hospital identifying increasing inevitable injected injection inserted integrating integration intervention listed lists locations longitudinal maintained management maps match materials matrix medical medicine medium memorial middle minimal models obstetrics optimized original output overlapping partial particular pass period permeability physics placed previous problematic processing profile promising quantification quantifying radiological rats recirculation reduced resolution saturated saturation sciences selected separated serve side significantly silicone singular sinus slice slopes software started stroke studies susceptibility system table temporal therapy throughout variability variance variate variation variations varied vein venous versus vessel volume whole