MR Microscopy of Diseased Human Skin Using Phased-Array of Microcoils at 9.4 T: First Results

Katharina Gbel1, Oliver G. Gruschke2, Jochen Leupold1, Johannes S. Kern3, Cristina Has3, Jan G. Korvink2, 4, Leena Bruckner-Tudermann3, 4, Jrgen Hennig1, Dominik von Elverfeldt1, Nicoleta Baxan1, 5

1Dept. of Radiology, Medical Physics, University Medical Center Freiburg, Freiburg, Germany; 2Lab. of Simulation, University of Freiburg - IMTEK, Freiburg, Germany; 3Dept. of Dermatology, University Medical Center Freiburg, Freiburg, Germany; 4Freiburg Institute for Advanced Studies, University of Freiburg, Freiburg, Germany; 5Bruker BioSpin MRI GmbH, Ettlingen, Germany

MRI of the skin as non invasive alternative to histopathology is challenging as dedicated approaches are required to overcome low sensitivity and contrast of standard MR investigations applied at microscale. The geometry of the skin with layers of large lateral dimensions and micrometre thickness demands high resolution over an enhanced FOV. Here, a home made MR detector arranged in a phased array geometry has been developed to surmount these challenges. Based on findings about coil performance and feasibility of high resolution imaging on healthy human skin, we present first results of diseased skin (Acne inversa) with direct comparison to histopathological sampling.

Keywords

accelerate accurate accurately acne acquisition advanced affected applied approaches arranged array axial axillary better biology biopsies biopsy bond bottom brighter challenging channels chip chronically circuitry clearly coil coils combined configuration consecutive consists contact container content contrast coronal currently dedicated depicting dept dermis design detection detector developed device diagnostic diagnostics differentiation dimensions direct disease diseased disorder efficiency enable enabling environment epidermis epithelial establish examination expected extremely findings fistula fundamental geometry gradient healthy histological histology home human identify individual inflammation inflammatory invasive investigations keep layer layers linearly location matrix medical methodological microscopy mode morphology mounted necessary nest next nutrient oliver oriented outer overcome overlapping package pads parallel pathological penetrating performance physics physiology polarized previous procedure procedures radiology receive relapsing required resolution reveals sample screening sensitivity seven shape side simplification simulation sinus site situation skin slice slices solution staining strategies structural structure subsequently suitable surface system therapeutic together transmit tuning typical understanding view water