Meeting Banner
Abstract #2816

MR-Compatibility of a SiPM-Based PET Detector Module Using HDMI for Analog Readout and Power Supply

Jonathan D. Thiessen1, Eric Berg2, Chen-Yi Liu, 13, Daryl Bishop4, Piotr Kozlowski5, 6, Fabrice Retire4, Vesna Sossi6, Greg Stortz6, Christopher J. Thompson7, Xuezhu Zhang1, Andrew L. Goertzen1, 3

1Radiology, University of Manitoba, Winnipeg, Manitoba, Canada; 2Biomedical Engineering, University of California, Davis, Davis, CA, United States; 3Physics & Astronomy, University of Manitoba, Winnipeg, Manitoba, Canada; 4Detector Development Group, TRIUMF, Vancouver, British Columbia, Canada; 5Radiology, University of British Columbia, Vancouver, British Colubmia, Canada; 6Physics & Astronomy, University of British Columbia, Vancouver, British Columbia, Canada; 7McConnell Brain Imaging Centre, Montreal Neurological Institute, Montreal, Quebec, Canada

An MR-compatible PET detector module featuring a silicon photomultiplier coupled to a dual-layer LYSO scintillator crystal array and using an HDMI cable for supplying power and bias as well as transmitting analog signals was tested in a 7 T Bruker MRI. Performance of the PET detector was evaluated inside the MRI as was performance of the MRI with the PET detector present and operating. Given the limited interactions between the operating PET detector module and MRI, the current PET detector design appears to be a viable first step in creating an MR-compatible full-ring PET system.

Keywords

absolute accomplished acquisition adjacent although amplitude analog analyzer appears array astronomy attached attributed bandwidth benefit berg bias biomedical board bottom brain cable cabling card characteristics circuit clinical coil compatibility compatible configurations connector connects consists constructed copper corrected cost coupling creating cross crystal crystals decrease decreased dependent design detector development deviating differential directly double dual electronics ended energy engineering evaluate evaluated extent featuring field flash flood frequency full functional health histogram histograms homogeneity hong housed hung immediately individual influence initial inner inside intensity inter interactions king known layer long magnet maps matrix measured mode module modules molecular monitored multimedia network neurological operating opposite orientation outputs outside performance phantom pharmaceuticals phys physics placed planar plus power processes pulse quality radioactively radiology rare readout repeated repetitions resistor resolution ring robust sections series shaping shielded shielding sided silicon slice solution source suggesting superior supplying system systems temperature thick threshold timing transmitting trap unchanged visible volume