Meeting Banner
Abstract #2747

Design, Evaluation and Application of a Six-Channel Transceiver Array Tailored for In Vivo Human Eye Imaging at 7.0 T

Andreas Graessl1, Michael Schwerter1, Maximilian Muhle1, Jan Rieger1, 2, Celal Oezerdem1, Abdullah Ok1, Davide Santoro1, Darius Lysiak1, 2, Oliver Stachs3, Soenke Langner4, Paul-Christian Krueger4, Thoralf Niendorf1, 5

1Berlin Ultrahigh Field Facility (B.U.F.F.), Max-Delbrueck-Center for Molecular Medicine, Berlin, Germany; 2MRI.TOOLS GmbH, Berlin, Germany; 3Department of Ophthalmology, University of Rostock, Rostock, Germany; 4Institute for Diagnostic Radiology and Neuroradiology, University of Greifswald, Greifswald, Germany; 5Experimental and Clinical Research Center, Berlin, Germany

In vivo imaging of the spatial arrangement of eye segments and their masses is an emerging MRI application and ultimately aims at performing MR image-based biometry. For this purpose, a six-element transceiver eye coil array (f=298 MHz) which uses loop elements is proposed. Our EMF simulations and experimental results indicate that the use of multiple surface coil transceiver loop elements yields an excellent SNR for eye imaging, affords uniform signal intensity across the eyes, and facilitates the depiction of anatomical details of the eye.

Keywords

absorption acceptable accomplished achieved acquisition aims anatomy anterior appealing application array artifacts audience basic biology bottom broad cables capacitor capacitors channel clinical clinically clinicians coaxial coefficients coil common conducted conductor conforms conjunction connection considerations constraint contrast correct correlation coupling cover covering decoupling deposition derived design details diagnostic dimensions distribution duke efficiency electro element elements engineering engineers established examined experimental exploration eyes facilitates family fiber field five gain geometries glucose guidelines hardware head heating human illustrated in vivo individual induced intensity journal layout loop masses measured medicine mimic minutes molecular motion neighbor next noise novel numerical oliver ophthalmology optic optical optimized permitted phantom placed planar plastic power precursor preparation probes proposed pulse pursue radiology rather reduce reflection resolution revealed scanner segments setting setup share simulations solutions space spatial spheres splitting subjects surface system tailored tailoring target temperature tools transceiver transmit transverse trimmer tubes ultimately ultrahigh uniform uniformity validate validated view virtual volunteer volunteers width