Meeting Banner
Abstract #2684

A Novel Golden-Angle Radial FLASH Motion-Estimation Sequence for Simultaneous Thoracic PET-MR

Chuan Huang1, Joyita Dutta1, Yoann Petibon1, Timothy G. Reese2, Quanzheng Li1, Ciprian Catana2, Georges El Fakhri1

1Center for Advanced Radiological Sciences, Department of Radiology, Massachusetts General Hospital, Boston, MA, United States; 2AA Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, United States

Accurate lesion characterization is crucial for initial staging, follow up and assessment of response to treatment in non-small cell lung cancer. Conventional PET-CT suffers from a temporal mismatch between PET and CT, due to longer PET than CT acquisitions needed for achieving good PET SNR. This mismatch yields artifacts that affect PET diagnostic specificity as well as quantitation accuracy. Gated CT can be used to correct these motion artifacts; however, however, this is not usually done routinely due to longer exams and greater radiation dose. In this work, we present a slice-interleaved golden-angle radial FLASH sequence with short-duration slice-projection navigation for lung respiratory motion measurement and respiratory motion tracking for motion-corrected PET reconstruction using simultaneous PET-MR.

Keywords

absent according accurate achieving acquisition activity advanced affect agrees although arrow artifact artifacts attenuation banana bandwidth biograph biomedical blood blurring cancer cell challenging characterization chosen close consideration coronal correct corrected corresponds course cover crucial detect diagnostic diaphragm dominated done dose endeavor enhance entire especially estimation even exam exams except excitation expectation extract fashion fast field fields flash flexibility formula future general golden good greatest hospital in vivo incorporated induced initial injected intensity interleaved ionizing lack larger lead lesion lesions limit longer lung magnification magnified makes maps mismatch modality motion movement mushroom navigation near novel onto overlaid plot position positioning preliminary prescribed prescription processed projection prominent promising proposed pulse radial radiation radiological radiology real reconstructed reconstruction reduced registration remains resolution respectively respiratory response routinely samples schematic sciences sensing short simultaneous slice slices spatial specificity studies suffers suppl temporal thoracic timothy track tracking treatment uncorrected underestimation validate validated vertical vessel visible volume volumes yellow yields