Bz-SNR-Enhanced Echo-Shifted Incoherent Steady State Imaging for Electrical Conductivity Mapping

Hyunyeol Lee1, Woo Chul Jeong2, Hyung Joong Kim2, Eung Je Woo2, Jaeseok Park1

1Brain and Cognitive Engineering, Korea University, Seoul, Korea; 2Biomedical Engineering, Kyung Hee University, Yongin, Gyeonggi, Korea

Magnetic resonance electrical impedance tomography (MREIT) was recently introduced to achieve high spatial resolution, wherein the internal magnetic flux density (Bz) induced by current injection results from image phases and electrical conductivity is then calculated using the harmonic Bz algorithm. To achieve accurate conductivity distribution in tissues, a high signal-to-noise ratio (SNR) in Bz is critical, which is proportional to the product of current injection time (TC) and SNR in magnitude image. To effectively enhance the SNR of Bz in MREIT and speed up data acquisition, in this work we develop a Bz-SNR-optimized echo-shifted incoherent steady state imaging pulse sequence for accurate quantification of electrical conductivity, wherein free induction decay (FID) signals experience multiple current injections to form an echo without apparent loss of signals while retaining high imaging efficiency.

Keywords

accuracy accurate achieve acquisition adjusted adopted agar alternating among amplitude amplitudes apparent assuming background becomes biological biomedical brain career certain cognitive coil combination comparable conditions conductivity contrast correspondingly cover critical cross cylindrical decay decreases density depending develop diagnostic directly distribution effective effectively efficiency electrical electrodes engineering enhance enhanced enhancing equation expected experience fashion flux fold form free gradient guarantee harmonic homogeneous impedance incoherent increasing induced induction inhomogeneity injected injection injections interleaving internal introduced investigate long loss magnetizations magnitude mapping materials matrix meas model necessarily negative noise note numerical numerically objects optimal optimized orthogonal package pair park particularly pathological phantom physiological polarities positioning positive potentially produces product program promising proportional proposed providing pulse pulses quantification reconstructed reconstructing reconstruction remove researcher resolution respectively retaining rises saline schematic sections simulated simulations since slice slices software solution solutions spatial spectral speed spoiled spoiler steady steps strategy tissues tomography trans transverse trio valuable varies wherein whole