Meeting Banner
Abstract #2428

Multifrequency MRE of Human Liver Specimen: Sensitivity of Viscoelastic Powerlaw Constants to the Collagen Matrix in Hepatic Fibrosis

Ingolf Sack1, Rolf Reiter1, Korinna Joehrens2, Andreas Fehlner3, Sebastian Hirsch1, Jing Guo4, Rajan Somasundaram5, Daniel Seehofer6, Carsten Kamphues6, Abbas Samani7, Juergen Braun8

1Department of Radiology, Charit - Universittsmedizin Berlin, Berlin, Germany; 2Department of Pathology, Charit - Universittsmedizin Berlin, Berlin, Germany; 3Department of Radiology, Charit University Medicine, Berlin, Germany; 4Department of Radiology, Charite - University Medicine Berlin, Berlin, Germany; 5Interdisciplinary Rescue Center, Charit - Universittsmedizin Berlin, Berlin, Germany; 6Department of Transplantation Surgery, Charit - Universittsmedizin Berlin, Berlin, Germany; 7Department of Electrical & Computer Engineering, University of Western Ontario, London, Ontario, Canada; 8Institute of Medical Informatics, Charite - University Medicine Berlin, Berlin, Germany

Elastography has been established for the clinical assessment of liver fibrosis. However, little is known about the relationship between viscoelastic constants and pathophysiological mechanisms in the liver. In this study, samples of the liver of 16 patients with different degrees of fibrosis, inflammation and steatosis were investigated by wide-range MRE and by static indentation for the interaction between mechanical constants and structural parameters of human liver according to histology, matrix protein quantification and function tests. As a main result, MRE was the most sensitive modality to the degree of fibrosis outperforming static indentation experiments and chemical quantification of matrix proteins.

Keywords

according albeit allow although amount amounts amplitude analyzed appears applied approximately architecture arrangement assigned biological boundary bovine clinical cohort collagen complex computer conditions constants container content contributor correlated correlation cutting cycles cylinder decay decreased degree density described despite detected determined diagnostic distribution drilled dynamic elasticity electrical engineering established except excitation exponent fewer fibrosis findings flow frequencies function functional functions furthermore geometrical geometry global hepatic hierarchic histological histology human immediately increasing indentation indenter indicates indicating inflammation influence informatics insight insignificant institution interaction interdisciplinary intra inversion irregular known lesions limited linear literature liver loading macroscopic major maps marker measure measured mechanical mechanically mechanisms modality model modulus neither network noninvasive patients period power preparation problem properties radiology reason related relationship reliable resection revealed sample samples scores sensitive sensitivity shape shear significantly sophisticated staging staining static stiffness stimulating strain structural subjected success suitable surgery system table tissue transformation transplantation trend type uncertain viscoelastic visualized western