Meeting Banner
Abstract #2103

Measurement of Apparent Diffusion Coefficients of Hyperpolarized 13C-Metabolites In-Vivo

Franz Schilling1, 2, Jan Henrik Ardenkjr-Larsen3, Martin A. Janich2, Marion I. Menzel2, Lise Vejby Sgaard3

1Institute of Medical Engineering, Technische Universitt Mnchen, Garching, Germany; 2GE Global Research, Garching, Germany; 3Danish Research Centre for Magnetic Resonance, Copenhagen University Hospital Hvidovre, Hvidovre, Denmark

We suggest a new approach to characterize the metabolism by performing apparent diffusion coefficient (ADC) measurements of hyperpolarized metabolites in-vivo. A diffusion-weighted pulse sequence was developed based on the pulsed gradient spin echo with low flip angle (α = 20˚) slice selective excitation in combination with a band-selective universal-rotation refocusing pulse optimized by optimal control theory. In two rats, we acquired 13C-metabolite ADCs in 3 spatial directions from lactate, alanine and pyruvate in muscle tissue at 4 different positions. The analysis of diffusion properties of intracellularly produced hyperpolarized compounds might potentially be useful for characterizing pathological changes in tumor cells.

Keywords

acknowledges acquisition activity alanine allow amplification amplitudes apparent array assuming axial bandwidth biomedical cells cellular channel characterize chosen coefficients coil combined compartment compartments compounds confined consistent consisting containing continuing control conversion corrected correction cost covering damping danish dataset decay depends designed detect diffusion dissolution distribution element elements enzyme equation equivalent even exchange excitation excitations exemplary experiment exponential expression fitted fold frequency funded funding global glycine gradient grant in vivo individual injected injection institute instruments intensities intracellular inversion kinetics lactate long loop loss maps medical membrane metabolism metabolite metabolites might modified mono muscle nuclei offset optimal optimized oxford pathological peak phantom plasma polarizer pool positions potential principle properties property protocol proving pulse pulsed quantitative rapid rats real receive refocusing repeated respective robustness rotation scanned scheme schilling selective selectivity separated slice spatial spectroscopy spins stable starting structure studies suggest tail tanner term thigh tissue transmit transmitter treatment tumor tumors universal urea useful vitro volume yielded