Abstract #1691

Improved Accuracy and Precision in Estimation of Intracellular Water Liftime

Jin Zhang1, Melanie Freed2, Joe Rodriguez3, Daniel H. Turnbull3, 4, Sungheon Kim1

1Radiology, Center for Biomedical Imaging, New York University School of Medicine, New York, United States; 2Radiology, Center for Biomedical Imaging, New York University School of Medicine, New York, United States; 3Kimmel Center for Biology and Medicine at the Skirball Institute of Biomolecular Medicine, New York University School of Medicine, New York, United States; 4Radiology, New York University School of Medicine, New York, United States

Intracellular water lifetime can be a useful non-invasive biomarker to probe the viability of cell membrane. However, accurate measurement of intracellular water lifetime remains challenging. In this study, we proposed to use multiple flip angles for DCE-MRI data acquisition in order to improve both accuracy and precision of the estimation. The proposed method was investigated using a numerical simulation study as well as a preclinical study with mouse tumor models. Our preliminary results support that the proposed method can substantially reduce the uncertainty in the measurement of intracellular water lifetime.

Keywords

accuracy accurate acquisition addition animal approved arterial assessed assumed better biology biomedical black blue body bolus bore breast calculation cancer care cells choice chose circles closely coil combination combined committee compartmental compartments completely conducted constant contrast contributions conversion cross crosses curve curves depends describe diagnosis diffusion diffusivity dose duration dynamic enhanced estimation example examples exchange experiment extracellular feasibility flash frames function future general generalized generated gradient half hindered horizontal hypothesis hypothesized identify importance improved improvement in vivo indicates induced injected injection input institutional inter interquartile intracellular kinetic larger lifetime linear longer magnet maintained materials matrix measure measured medians medicine mice model monitoring mouse muscle numerical optimal pair paramount particularly precision quartile quirk radiology realistic receive reduced related resolution response restricted scanned school series shape simulated simulation site slope space starting steps stimulated substantially suggests summary temperature temporal terms tile tissue tracer trade trans transmit treatment true tumor uncertainty understanding univ volume warranted water