Meeting Banner
Abstract #1562

Glomerular Imaging of Mouse Kidney Using a Dedicated Alderman-Grant Probe

Jorge Chacon Caldera1, Philipp Krmer1, Raffi Kalayciyan1, Lothar R. Schad1, Sabine Neudecker2, Stefania Geraci2, Norbert Gretz2

1Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany; 2Institute for Medical Technology, Heidelberg University, Mannheim, Germany

The filtration of the blood to maintain balance between salt and water, and the waste elimination is performed in the kidneys by the glomeruli. Glomerular number is, therefore, a very important indicator of the functioning status of the kidneys. Quantification of glomeruli could help diagnose kidney malfunctioning and prevent CKD. The Alderman-Grant resonator is a volumetric probe, which solves the problem of homogeneity; it has good response in UHF so it can be flexible in the dimensions while being efficient at high field NMR [4]. An Alderman-Grant resonator was chosen for its characteristics that match the requirements of the glomerular imaging, and a dedicated MRI probe was built. A comparison between a cryogenic surface probe and the dedicated AVR probe for glomerular imaging is presented.

Keywords

able access accommodate achieved alderman analyzer appear appearing arise assisted axis balance biomedical blood bore bottom build built caldera capacitors causing choice chronic clear clinical coil coils complicate complicates compromising concluded connected connections copper coronal cost couples created cryogenic dedicated described design designs despite dial diameter dimensions disadvantages disease distribution done efficient eliminate exact expected field fields filtration flash forces frequencies frequency future good grant great ground guard guardian health heterogeneous highly homogeneity improved inductance inhomogeneity inhomogeneous initial inside isotropic kidney kidneys length loaded malfunctioning matching materials matrix measured medical medicine mouse near noise obvious overcome perfect pixel placed prevent probe problem problems profile proven quantification quantified quantitative recent reduction resistance resolution resonant resonator response ring rings salt sample samples schematic segment segmentation segments sensitivity side since slab slice slices solenoid solved solving spots suggestion suits superior surface taken tape technology temperature transplant tuning type unloaded variable visible visual volumetric wings