Meeting Banner
Abstract #1253

Cerebral Blood Flow: Comparison Between Ultrasound and Phase Contrast MRI

M. Ayaz Khan1, 2, Jie Liu1, 2, Peiying Liu3, David Zhu4, Hanzhang Lu3, Rong Zhang1, 2

1Cardiology, University of Texas Southwestern Medical Center, Dallas, TX, United States; 2Institute for Exercise and Environmental Medicine, Dallas, TX, United States; 3Advance Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX, United States; 4Cognitive Imaging Research Center, Michigan State University, East Lancing, MI, United States

Quantitative blood flow measurement is essential for assessment of cerebrovascular function under normal and diseased conditions. Color-coded duplex ultrasonography (CDUS) and phase contrast (PC) magnetic resonance imaging (MRI) are two commonly used non-invasive techniques for measuring CBF. However, previous studies showed substantial differences between these two methods. Recent development in ultrasoud technology and quantification of blood vessel diameter using the edge-detection and wall-tracking method have significantly improved the accuracty of CBF measurement using CDUS. In the present study, we compared CBF meauserments using the PC MRI with the high-resolution 2-D CDUS methods.

Keywords

advance alcohol although analyzed analyzer applications applied array arteries artery asked assessment averaging beverage bifurcation blood brain cardiac cardiology carotid cerebral channel clinical coded coefficient cognitive coil collected collection color commonly complete conditions consecutive considered contrast controls corrected correlation correlations cover cycles detection development diameter diseased distance drawn duplex east edge eight encoding enhance entire environmental essential exercise flow function gated generated head hours identified improved institute intensity internal intrinsic invasive khan lancing larger layers least length linear listed lumen magnitude major manually masks measure measured measuring medical medicine minutes moment multiplying parallel participated perpendicular placed position positioned previous product quantification quantitative receive recent recorded reflect refrain remained resolution resting sample segment segments settings significantly site slightly southwestern stabilize statistically straight studies subjects substantial supine system systems table technology thirty tracking transducer transmit ultrasound uniformity variability velocity vertebral vessel vessels view volume volumetric wall waveforms