Meeting Banner
Abstract #1113

Extended Metabolite Profile of the Human Spinal Cord

Andreas Hock1, Bertram J. Wilm2, Erin L. MacMillan3, Roland Kreis3, Spyros S. Kollias4, Peter Boesiger2, Anke Henning2, 5

1Institute for Biomedical Engineering , University and ETH Zurich , Zurich, Switzerland; 2Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland; 3Dept. of Clinical Research and Institute of Diagnostic, Interventional and Pediatric Radiology, University of Bern, Bern, Switzerland; 4Institute of Neuroradiology, University Hospital of Zurich, Zurich, Switzerland; 5Max Planck Institute for Biological Cybernetics, Tbingen, Germany

Clinical magnetic resonance spectroscopy is rarely applied in the spinal cord due to technical challenges leading to a low spectral quality and thus to a limited number of reliable detectable metabolites. In order to extend the metabolite profile an increase of the spectral quality is necessary, which could be achieved by both: averaging a high number of FIDs and by using a dedicated neck coil. Besides N-acetyl aspartate, creatine, choline and myo-inositol a reliable detection of scyllo-inositol and glutamine/glutamate was possible. Increased myo-inositol/creatine and scyllo-inositol/creatine ratios compared to brain estimates can be observed in the spinal cord.

Keywords

acquisitions addition additionally ahead alignment allows altered alternative applied approaches array attainable available averaging best bingen biological biomedical biomedicine blue bounds brain built caution cervical challenges choline clinical close closely coil combination combined comparing composition comprised concentration conditions constructive cord cram custom cycling dedicated derived detection diagnostic displayed distortions element enables engineering even every extended feasible female findings fingerprint fitting frequency full furthermore future gain glutamate gold green half henning hock home hospital human identified improve improving in vivo include inner institute investigation lack lead limit limited localization long markers measured metabolite metabolites might month neck note offering original overcome peak pediatric peter physiology placed placement possibility post potentially press previously print problem profile projection protocol providing quality quantification quantified radiology rarely reason related reliable reliably reported residuals saturation sensitivity session shimming spectra spectral spectroscopy spectrum spinal still strong substantial suppressed susceptibility table technical thanks thereby together triggered validation volume volunteer water width