Meeting Banner
Abstract #0753

Combined Intraneural Microstimulation and High Resolution fMRI at 7T

Rosa M. Sanchez Panchuelo1, Rochelle Ackerley2, Paul M. Glover3, Bader Al Debasi3, Richard W. Bowtell3, Johan Wessberg2, Susan T. Francis3, Francis McGlone4

1Sir Peter Mansfield Magnetic Resonance Centre , University of Nottingham, Nottingham, United Kingdom; 2Physiology, University of Gothenburg, Gteborg, Sweden; 3Sir Peter Mansfield Magnetic Resonance Centre, University of Nottingham, Nottingham, United Kingdom; 4Cognitive Neuroscience, Liverpool John Moores University, Liverpool, United Kingdom

We successfully performed microstimulation of single afferents in the environment of an ultra-high field (7T) MR scanner and collected high resolution fMRI data depicting the response to intraneural microstimulation. fMRI data were acquired for increasing current amplitudes during microstimulation of four different afferents in two subjects. Robust responses were found for all units, consistent with the activation pattern seen on applying vibrotactile stimulation to the receptive fields of the microstimulated units. Activation was not found for microstimulation at sub-sensation thresholds. High-resolution fMRI allowed the discrimination of the responses of microstimulation to single afferents located in the palm and middle finger.

Keywords

acquisition activation adapting additional afferent afferents aims alone amplitude applied assess assessed assessment beta blue bore bursts buzzing carefully central characteristics classes clear cluster cognitive combined completed confirming consisted consistent corrected cortex cortical coupled cutaneous cycles define delivered delivering derived distinct distinctly dramatically duration electrical elicited examined except exploration extends felt field finger fitted five flutter foundation frequency glover hill hours human increasing individual individually inserted intensity involved isolated john just kingdom localized location loss magnet mapped maps matched measured mechanical median middle motor moved nerve noise novel outside overlapping palm paradigm participated patterns perceived percept perception perceptions percutaneously peter physiology previously projections protocol pulse pulses rapidly receptive recruited recruitment reflecting relief repeated reported resolution resolve response responses rest robust runs scanner sensation sensations sensory session simultaneous slice statistical steps stimulated stimulation stimulus structural studies subject subjects successfully supplementary threshold thresholds timings topographically tungsten typically ultra unit units validate wave yellow