Meeting Banner
Abstract #0748

Intra-Individual Assessment of the Bolus Properties of 0.5M Gadopentetate Dimeglumine and 1.0M Gadobutrol in Time-Resolved Contrast-Enhanced 4D-MRA and Dynamic CT in a Minipig Model

Dariusch Reza Hadizadeh1, Gregor Jost2, Hubertus Pietsch2, Martin Weibrecht3, Marco Lierfeld4, Jack Boschewitz1, Hans H. Schild1, Winfried Albert Willinek1

1Radiology, University of Bonn, Bonn, NRW, Germany; 2MR and CT Contrast Media Research, Bayer Healthcare, Berlin, Germany; 3Research Laboratories, Philips Technologie GmbH Innovative Technologies,, Aachen, NRW, Germany; 4Institute of Imaging & Computer Vision), RWTH Aachen University, Aachen, NRW, Germany

Time-resolved contrast-enhanced MRA (4D-MRA) is more and more applied in various clinical indications and optimization of the applied contrast agent bolus is crucial. The impact of 1molar concentration on vascular gadolinium concentration (dynamic CT) and signal levels (4D-MRA) was investigated in an animal model of 7 Goettinger minipigs. Transversal slices covered the ascending aorta, descending aorta, and pulmonary trunk. Signal levels, the bolus profile and Gd-concentrations were quantified using 1.0M Gadobutrol (1.0GB) and 0.5M gadopentetate dimeglumine (0.5GD). 4D-MRA offered significantly higher signal and dynamic CT allowed for quantification of respectively higher peak Gd-concentrations using 1.0GB vs. 0.5GD.

Keywords

agent agents allow anesthesia angiography animal animals aorta application applied approval approved ascending assessment axial background basis better body bolus breath calculations carried choice clinical committee complete compliance computer concentration concentrations contrast corresponded crucial curve curves days decreasing descending described detected determine determined doses dynamic dynamics enhanced enhancement especially examinations examined feed female flow flushes focuses full function gadolinium gamma griffin half handled holds impact included indications individual injection innovative institute intensity intervals intra invest investigate investigated jack kinetics laboratories latter legislation limitations martin measured media model molar months narrower offers optimized partial partitions peak peaks perfusion phantom placed placement positions post previous prior progress properties pulmonary quality quantifying quantitative radiology received regard relevant resolution resolved respective saline separation shape sharpness shorter significantly since slice slices song spatial studies systematically table technical technologies temporal thoracic transformed trunk twist update variate various vascular venous vessel vessels vision welfare whereas whole width widths