Meeting Banner
Abstract #0584

Slice Accelerated EPI for Dynamic-Susceptibility Contrast Enhanced (DSC) MRI

Dingxin Wang1, 2, Charles G. Cantrell3, Bruce S. Spottiswoode4, Vibhas Deshpande5, Timothy J. Carroll3, Keith A. Heberlein6

1Siemens Medical Solution USA, Inc., Minneapolis, MN, United States; 2Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, United States; 3Department of Radiology, Northwestern University, Chicago, IL, United States; 4Siemens Medical Solutions USA, Inc., Chicago, IL, United States; 5Siemens Medical Solutions USA, Inc., Austin, TX, United States; 6Siemens Healthcare USA, Charlestown, MA, United States

Our study demonstrates the feasibility of using slice accelerated EPI for DSC-MRI measurement and shows the evidence of association between sampling TR and perfusion parameters. The MTT and Tmax maps with faster TR sampling (509 ms) of perfusion data provide more image contrast than slower sampling rate (1527 ms). The difference in MTT also contributes to the variation of CBF spatial pattern. Faster data acquisition should reduce discretization errors in the perfusion measurement, especially for Tmax, as the measured Tmax is rounded-off to a value multiple of TR.

Keywords

accelerated acceleration acknowledge acquisition additionally agent aliased allow analyzed appear apply approval arrows artery association authors bandwidth blood body bottom brain care cerebral channel clinical coil compute consent console contrast correction coverage curve delay demonstrating dependent derived developed discretization dispersion distribution distributions dose dynamic elevated enhanced errors especially evidence excitation excite exhibited experimentally fast faster feasibility flow fully function future gadolinium gradient greatly guidance head histogram included indicate injection integer intensity intravenous investigated long look maps markers matrix measure measured medical middle minutes natl neck need northwestern parallel parametric part partial patient pattern perfusion posterior prognostic pulses qualitatively quite radiology rapidly receiver reconstruction reduce reduced reduces related relatively representative residue resolution rounded sampled sampling scanner seem selected sensitivity separate simulate simultaneously slice slices slower smith solution solutions spacing spatial stroke studies subtle successfully support susceptibility temporal therapeutic timothy tissue tool transit typical unaccelerated variation various volume volunteers watershed whole wish written