Meeting Banner
Abstract #4252

Noise from Non-Cone Regions in Segmented K-Space Contributes to Artifacts in Quantitative Susceptibility Mapping

Shuai Wang1, 2, Tian Liu3, Weiwei Chen4, Pascal Spincemaille2, Yi Wang, 25

1University of Electronic Science and Technology of China, Cheng Du, Si Chuan, China; 2Radiology, Weill Cornell Medical College, New York, United States; 3MedImageMetric LLC, New York, United States; 4Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science&Technology, Wuhan, Hubei, China; 5Biomedical Engineering, Cornell University, Ithaca, NY, United States

Several Quantitative Susceptibility Mapping (QSM) methods have been proposed to obtain tissue magnetic susceptibility in vivo. We compared various QSM methods in order to identify a robust QSM for clinical applications. We found that noise from the non-cone region in k-pace where the dipole inversion has been regarded as well behaved can contribute to substantial streaking artifacts in QSM. An accurate QSM needs address noise in the entire k-space, and not just the cone region. Evaluation on 21 consecutive patients indicated that the image space based morphology enabled dipole inversion is the most robust among three evaluated methods.

Keywords

abnormalities abnormality account additional address addressing allow amount apparent artifacts attempting balance best biomedical blinded blurring bottom brain categories categorize certain characterized china circumvent clinical college completely compressed concept cone consecutive contributes contribution corpus cortical derivative dipole division domain echoes either electronic eleven engineering evaluated example except exhaustive experienced explained explicit express fidelity field focused forward free fundamentally galen generated generates give gradient gray hemorrhage hospital huge hybrid identify illustrated increasing interface inverse inversion investigated just kernel known lack lesion lesions local many mapping mathematical matrix measured medical middle mimicking missing moderate near noise nonuniform nucleus numerical optic optimized pascal patient patients people phantom plus posed previous problem propagation properties quantitative radiology reconstruction referred regularization republic resolution respectively robust science scientific scored scores search sensing severe simulated slice solutions sort space spaces spatially statistically streaking subject superior superiority suppression surface susceptibility system technology thalamus threshold tissue transform uniform various vein zero