Meeting Banner
Abstract #4219

A Novel Pulse Sequence to Measure Oxygen Extraction Fraction in the Brain Using Parameter Assessment Using Retrieval from Signal Encoding (Parse) Techniques

Rajiv G. Menon1, Bradley P. Sutton2, Donald B. Twieg3, Timothy J. Carroll1

1Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, United States; 2Bioengineering Department, University of Illinois at Urbana-Champaign, Urbana, IL, United States; 3Biomedical Engineering Department, University of Alabama at Birmingham, Birmingham, AL, United States

We propose a novel technique for the measurement of oxygen extraction fraction (OEF) using Parameter Assessment by Retrieval from Signal Encoding (PARSE) techniques. OEF is a key indicator of cerebral perfusion and gives crucial information regarding the stage of vascular compromise in patients with neurovascular disease. PARSE is an efficient, multi-parameter estimation technique, that uses a more accurate signal model to simultaneously measure M0, R2* and local frequency. By direct measurement of local frequency changes due to OEF related susceptibility changes using PARSE, we determine the feasibility of robustly estimating OEF in pathological situations.

Keywords

abnormalities accuracy accurate accurately acquisition addition adoption advanced analyzed arterioles assess assessment availability bars bioengineering biomedical brain calibration capacity caused champaign combination conclude conditions conjugate cost crucial currently cyclotron delivered designed detect determine deviations directly disease done drawbacks efficient efficiently emission encoding engineering ensure equation equivalent error establish established estimation exceeded expect extraction extracts facility feasibility field filtered focal fraction frequencies frequency function gating gives gold gradient healthy house impairment implement implemented increasing induced insufficiencies inverse known length local location mainly measure medicine metabolism mild model much need noise northwestern novel numerical offset oxygen parse particular pathological patients positron priori progressive prohibitively proposed psych pulse radiology reached realized reasonable regarding related remain represent required requirements resolution respiratory retrieval robustly rosette scale scanner school sensitivity setback severe shimming simulations simultaneously since situations stage starts strength stroke studies suffice susceptibility target timothy tissue tomography trajectory translates trio unchanged usage useful validate validated vascular