Abstract #3884

Comparison Between Breath-Hold and Navigator-Gated Magnetization-Prepared 3D Steady-State Free Precession for Nonenhanced Renal Magnetic Resonance Angiography

Huan Tan1, Ioannis Koktzoglou1, 2, Christopher Glielmi3, Mauricio Galizia4, Robert Edelman1, 4

1NorthShore University HealthSystem, Evanston, IL, United States; 2The University of Chicago Pritzker School of Medicine, Chicago, IL, United States; 3Siemens Healthcare, Chicago, IL; 4Northwestern University Feinberg School of Medicine, Chicago, IL

Nonenhanced, navigator-gated, inversion-prepared MR angiography technique (Nav SSFP) has proven accurate for evaluating the patency of renal arteries. However, the scan time of Nav SSFP can be excessive depending on breathing patterns. A highly efficient single-shot 3D SSFP technique was implemented to allow the full extent of the renal arteries to be depicted in a single breath-hold (BH SSFP). Overall, BH SSFP demonstrated comparable image quality, SNR and CNR in volunteers and patients despite a mean eight-fold reduction in scan time. The initial results suggested a potential supplementary clinical role for BH SSFP in the evaluation of suspected renal artery disease.

Keywords

accuracy accurately achieve acquisition addition address adequate ages allowable angiography applied approval arrow arteries artery artifacts asymmetrical available axially background band bandwidth breath cardiac channel chemical clinical commercially comparable computed consists coverage depend dependency depict depiction determine diagram diastole disease dual effectiveness eight eliminate encoding ensure evaluation except excitation experienced extra female flow fold fourteen free gated gating healthy hold identical illustrated implemented included increasing inferior inflow initial interval intra inversion isotropic issues length linearly long magnetization male matching medicine moderate motion native navigator optimize optimized oriented parallel partial patient patients patterns pixel potential preference preparation prepared prescribed projection protocol pulse quality quantitative radiologist radiology readout receiver recruited reduce reduced reduction renal reported required resolution respectively reverse role sampling saturation scanner scheme school scored scores selective session seven short shot slab slabs slice steady subject suboptimal sufficiently suggest suppress suppression suspected synchronization systole targeted technical trajectory triggering venous view volunteer volunteers