Meeting Banner
Abstract #3851

Cardiac Motion-Corrected Inversion Prepared Real-Time (TIRT) Cine TrueFISP Imaging for Rapid Myocardial T1 Estimation

Andreas Greiser1, Hui Xue2, Peter Schmitt1, Matthias Dieringer3, 4, Florian von Knobelsdorff-Brenkhoff3, 4, Thoralf Niendorf3, 4, Jeanette Schulz-Menger3

1Siemens AG, Healthcare Sector, Erlangen, Germany; 2Siemens Corporate Research, Princeton, NJ, United States; 3Berlin Ultrahigh Field Facility, Max-Delbrueck Center for Molecular Medicine, Berlin, Germany; 4Experimental and Clinical Research Center (ECRC), Charit Campus Buch, Humboldt-University, Berlin, Germany

T1 mapping is promising for quantifying myocardial integrity. We propose a new method to rapidly (in 5 sec) map T1 in the heart based on an IR-prepared real-time Cine TrueFISP sequence combined with an elaborate motion correction. The method was validated against the established MOLLI technique in T1 phantom measurements as well as in vivo (n=10) and one myocardial infarction patient. Phantom results showed good match between methods. in vivo at 3T TIRT overestimated T1 by 12.9% pre and 17.7% post contrast, but with M0 and improved motion correction the method may become a valid alternative for myocardial T1 quantification.

Keywords

acquisition acquisitions administration agreement allows alternate always applied applying arrows attributed automated axis beneficial bias calibrated campus cardiac caution cell cine clinical combination comparable completely compromise contrast corporate corrected correction curve datasets dependence diastole direct elaborate eliminate employing enhanced enhancement estimation even exhibit existing experimental exponential extent extremely facility field fitting frames gadolinium good healthy heart implemented in vivo included indicate individual induced infarction instant integrity inversion investigated irrelevant jersey known late long mapping maps mated medicine might module molecular mono motion myocardial myocardium nevertheless noise nominal onset optimization overestimate patient perfect performance peter phantom pixel post preliminary prepared probably promising propose proposed proved pulse quantification quantifying rapid rapidly rather readouts real recovery reduce reduced register registration relatively remote remove resolution respiratory revealed rigid robust sample scanner scar sector short shortened shot significantly since slice spatial strong studies subjects suffer susceptibility synthetic systole taken though throughout towards train typical ultrahigh underestimate underestimated volunteers