Meeting Banner
Abstract #3791

Cine DENSE for Assessment of Diastolic Function: Pulse Sequence Development and Initial Results.

MAGNA25Bhairav Bipin Mehta1, Andrew D. Gilliam2, Frederick H. Epstein1, 3, Michael Salerno, 34

1Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, United States; 2A.D. Gilliam Consulting, Providence, RI, United States; 3Department of Radiology, University of Virginia, Charlottesville, VA, United States; 4Department of Medicine, Cardiology Division University of Virginia, Charlottesville, VA, United States

Heart failure with preserved ejection fraction (HF-PEF) resulting primarily from diastolic dysfunction accounts for more than half of all heart failure cases. Echocardiography is commonly used to assess diastolic function but has limitations affecting its measurement accuracy. Strain and strain rate measurement using cine DENSE MRI has advantages over echocardiographic techniques and could improve the diagnosis of diastolic dysfunction. Previous cine DENSE sequences have primarily imaged systole. With these sequences, SNR has degraded by mid-diastole, yielding inaccurate displacement measurements and strains. Here we modified a systolic cine DENSE sequence to image diastole with sufficient SNR to compute accurate diastolic displacements, strains, and strain rates.

Keywords

accordance accounts accuracy accurate achieve acquisition agrees allows angular apply approved arrow assess assessment atrial axis beat biomedical board bulk capable captured cardiac cardiology cine circumferential collected commonly compute computed consulting corrected curves cycle cycles cycling delay dense dependence described designed developed development diastole diastolic direct displacement displacements divided division duration dysfunction early echoes effective encoding engineering entire entirety every example failure field fixed frequency function funded gating healthy heart illustrate improve included inflow initial intensity investigate inward island late limit limitations magnitude maps matched matrix measures measuring mechanical medicine movement much myocardial myocardium noise operator optimal outward panel panels part peak position preferable preserved press previously primarily properties pulses quantitative radially radio radiology readout reduced reducing referred relatively resolution scaled scanner scheme section sharing short significantly since slice spiral stimulated strain strains strategy studies sufficient systole systolic temporal temporally thirds tissue trans typically uniform uniformly view volunteer volunteers wave windows