Meeting Banner
Abstract #3517

Comparison of Regional Perfusion Imaging Between Planning-Free Vessel-Encoded and Super-Selective Pseudo-Continuous Arterial Spin Labeling MRI

Nolan S. Hartkamp1, Michael Helle2, 3, Reinoud P.H. Bokkers1, Jeroen Hendrikse1, Matthias J.P. van Osch4

1Department of Radiology, University Medical Center Utrecht, Utrecht, Netherlands; 2Institute of Neuroradiology, Christian-Albrechts-Universitt, Kiel, Germany; 3Philips Technologie GmbH, Innovative Technologies, Research Laboratories, Hamburg, Germany; 4C.J. Gorter Center, Department of Radiology, Leiden University Medical Center, Leiden, Netherlands

The aim of this study was to compare the differences of perfusion territories determined by vessel-encoded and super-selective pseudo-continuous arterial spin labeling MRI. Cases are presented to illustrate the capability of either technique to determine correct perfusion territories in vascular variations and mixed perfusion areas. The results of this study show that perfusion territories of vessel-encoded and super-selective p-CASL RPI agree reasonably well. Vessel encoded ASL however fails to detect mixed perfusion areas, which leads to erroneous boundaries in these areas.

Keywords

accurate additional afterwards agree agreement allows although analyzed anatomical anterior arrow arterial arteries artery background basilar besides blood boundaries boundary brain caused cerebral closest cluster clustering combined communicating comparable complete configuration consecutive consisted contained continuous contribution correctly count currently delay described designated detect determined distance distances distinct drawbacks duration efficiency encoded encountered erroneous errors example examples extra failing feeding flow fourteen free hamburg hand healthy identified identify illustrate incapability innovative instead institute investigated investigating isolated label labeling laboratories larger leads localizer major manually matrix medical mismatch mismatches missing mixed observer otherwise outlined overall overlap part perfusion placing planning position positioning post posterior practical previous processing protocol pseudo radiology reasonably reflect regarding regional report reported reports reproducibility reproducible require robust scanner segment selective shot simply slice slices spatially spin spot star stroke super supplied suppression survey table technologies territories territory third unless variation variations varied versa vessel vice visualization volunteers whereas