Meeting Banner
Abstract #3515

Hippocampal Longitudinal Sub-Region Perfusion Can Be Reliably Measured Using ASL

Xiufeng Li1, Jeffrey S. Spence2, 3, Subhendra N. Sarkar4, David E. Purdy5, Gregory J. Metzger1, Robert W. Haley3, Richard W. Briggs, 36

1Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, United States; 2Clinical Sciences, UT Southwestern Medical Center, Dallas, TX, United States; 3Internal Medicine, UT Southwestern Medical Center, Dallas, TX, United States; 4Radiology, Harvard Med. School, Beth Israel Deaconess Med. Ctr., Boston, MA, United States; 5Siemens Healthcare, Malvern, PA, United States; 6Radiology, UT Southwestern Medical Center, Dallas, TX, United States

Measuring hippocampal longitudinal sub-region perfusion has significant clinical relevance, with potential for better diagnosis and understanding of healthy and pathological hippocampal physiology. To evaluate the reliability of measuring hippocampal longitudinal sub-region perfusion using arterial spin labeling (ASL) imaging, measurement errors due to both random spatial noise and temporal physiological noise in OPTIMAL FAIR ASL studies of rCBF were evaluated. Results indicate that hippocampal longitudinal sub-region perfusion can be reliably measured using ASL imaging.

Keywords

according acquisition administered advanced affairs affect agencies anatomy anterior application approved array arterial assumed attributed awake awarded axis beth better blood board body bolus cerebral channel clinical closed coil common compartment confined consent contract control correction cover customized deaconess density diagnosis differentiation differing disease eight either encoding endorsement errors evaluate evaluated eyes facilitate fair federal flow function government grant head healthy human inferior inferred informed institutional intensity internal interval inversion label labeling larger listed longitudinal materials matrix measured measuring medical model motion necessarily neurology noise numerous official optimal optimized oversampling pace pairs part partial partially particularly pathological pathology perfusion physiological physiology placed position prospective protocol proton pulse quantification radiology random reception reduced reflect regional reliability reliably remain represented required resolution saturation scanner school sciences screened selective selectively series shimming slab slice southwestern spatial spatially spin sponsoring studies subject subjects subregion supported table tail temporal transmission trio typical understanding whole width written