Meeting Banner
Abstract #3308

Cartilage Assessment in Femoroacetabular Impingement Using DGEMRIC with Radial Imaging Planes at 3 Tesla: Preliminary Validation Against Intra-Operative Findings

Riccardo Lattanzi1, 2, Catherine Petchprapa1, Daniele Ascani1, Roy I. Davidovitch3, Thomas Youm3, Robert J. Meislin3, Michael Recht1

1Radiology, New York University Langone Medical Center, New York, NY, United States; 2The Bernard and Irene Schwartz Center for Biomedical Imaging, New York University Medical Center, New York, NY, United States; 3Orthopedic Surgery, New York University Hospital for Joint Diseases, New York, NY, United States

Early diagnosis of articular cartilage degeneration is critical to the success of corrective surgical procedures for patients with femoroacetabular impingement (FAI). Delayed Gadolinium-Enhanced MRI of Cartilage (dGEMRIC) can detect early biochemical changes in articular cartilage. In this work we validated the technique for the hip at 3 T against intra-operative findings, using radial imaging planes and a method to standardize dGEMRIC measurements, in order to remove the effect of inter- and intra-patient variability. Sensitivity, specificity and accuracy were 86%, 55% and 73% for dGEMRIC, and 59%, 61% and 60% for morphologic evaluation, using corresponding proton-density-weighted radial images.

Keywords

abnormalities accuracy accurate acquisition affected aimed allow allowed alone among anterior arthroscopic articular artifacts assessment assumed bandwidth bars basis bearing beck biochemical biomedical bone bony cartilage central comprehensive considerably coronal correcting critical defects degeneration delay depicting detached detect diffusion directly discriminate diseases display documented either error evaluated evaluation experienced fact females femoral findings form fovea gadolinium healthy hips impingement improves include indicate injection injuries institution inter intra introduced joint label least lesions likely limited location macroscopic males mapping maps materials medical morphologic near operative orthopedic osteoarthritis overall patient patients performance pixel portion post posterior predict preliminary prevent previous processing proposed protocol proton pulse radial ranging readers received receiver recent recognized relatively relevant reliability reliable repair repeatability reported representative resolution respectively review routinely scores sensitive sensitivity since slice slices software spatial specificity standardize standardized suggesting suggests superimposed superior surgeon surgeries system table transformed underwent validate validates variability varied vary visualized whereas whole