Abstract #3294

Dynamic 3D T1 TFE Images of the Orbit with High Spatiotemporal Resolution at 3T

Marco Piccirelli1, 2, Chris Bockisch3, Roger Luechinger4

1SNS Lab, Dept. ECON, University Zurich, Zurich, Switzerland; 2Inst for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland; 3Departments of Neurology, Ophthalmology, and Otolaryngology, University Hospital Zurich, Zurich, Switzerland; 4Inst for Biomedical Engineering, University & ETH Zurich, Zurich, Switzerland

Dynamic MRI of the orbit during eye movement with high spatiotemporal resolution is possible using a segmented acquisition. Nevertheless, the excessively long resulting scantime prohibits clinical use. Therefore, methods are needed to decrease the examination duration, such as, e.g., multichannel receive array that will enable simultaneous scanning of both orbits and kt SENSE image acquisition. Simultaneous eye tracking enable the control of the reproducibility of the eye motion, and may be used for re-measurement of k-space profiles with wrong gaze direction. We present here methodological improvements that enable dynamic imaging of the orbit with high spatiotemporal resolution at 3T.

Keywords

ability able accelerates acceleration accuracy achieved acquisition amplitude array artifacts averaging avoid bands become best better biomedical black blurring cavities channel clinical coil continuous continuously control cycle cycles decrease decreased dependent dept deviation diameter disappear discarded drops duration dynamic efficient enable enables encoding engineering excessively fast feasibility field final frame frames frequent gaze good gradient hamburg horizontal hospital impacts imperfect impression improvements infrared inst laser long matrix median microscopy middle motion movement movements moving much multichannel necessary needed neighboring neurology nevertheless ophthalmology optimized oral orbit orbits outliers outside overall panel peak percentage performance periodic periodicity placed position potential preventing prohibits projected projector proven quality radiology readout real receive recordings rectangular rejection reported reproducibility resolution roger saturation scanner scanning screen segmented sense several shim shimming simultaneous sinusoidally slice slightly speed spreading strength stronger strongly subject subjects synchronized system target targets traces tracking training untrained update varies velocity video view volume worst wrong