Meeting Banner
Abstract #3191

Utility of Multiple B-Value DWI Derived Metrics in Differentiation of High Grade from Low Grade Glioma

Bhaswati Roy1, Rishi Awasthi1, Prativa Sahoo2, Ram KS Rathore2, Rakesh Kumar Gupta1

1Radiodiagnosis, Sanjay Gandhi Post Graduate Institute of Medical Sciences, Lucknow, India, Lucknow, Uttar Pradesh, India; 2Mathematics & Statistics, Indian Institute of Technology, Kanpur, Kanpur, Uttar Pradesh, India

Sixteen (11 male and 5 female; mean age=41 yrs) untreated consecutive patients (11 high grades & 5 low grades on histopathology) with a postoperative diagnosis of either high or low grade glioma were imaged on 3T scanner, using multi b-value DWI (0 to 2000s/mm2) and DCE MRI. On Students independent t-test, none of the DWI derived ADC, fp, Dslow and Dfast showed any significant differences between high and low grade glioma whereas all the DCE derived metrics except ve were found to be significantly higher in high grade as compared to low grade glioma. We conclude that multi b-value DWI is not a reliable technique to differentiate between high and low grade glioma and DCE perfusion MRI is still the best available technique to differentiate as well as characterize the glial neoplasm.

Keywords

accurate acquisition agents apparent appeared appropriate assess assessment assuming attempts available barrier best blood brain calculation central cerebral challenging characterization characterize coefficient coil component comprehensive concentration constant contrast corrected correctly correlate currently curve decay definitive derived develop diagnosis diagrams differentiate differentiating differentiation diffusion disagreement discriminate disrupted disruption dynamic dysfunctions efforts except exogenous extent fast field fitting flow flush fraction general grade grades grading histology important included initial injector institute intensity intercept intervention invasive inversion investigative lateral leakage lesion lesions limitations made manner maps materials mathematics matrix metrics model neoplasm none obviate patients pattern perfusion peripheral placed position post power powerful previous prior processing proved providing quantification quantify quantitative radiology recalled recovery reliable removing renal report reported represent require resolution respectively routinely scanner sciences significantly sixteen slice slices slow still strengths student studies superior surrounding susceptibility table taken technology temporal tissue transfer tumor tumors underwent untreated utility view volume whereas wide wise